Your browser doesn't support javascript.
loading
Validation of an experimental polyurethane model for biomechanical studies on implant-supported prosthesis: compression tests
Moretti Neto, Rafael Tobias; Hiramatsu, Daniel Afonso; Suedam, Valdey; Conti, Paulo César Rodrigues; Rubo, José Henrique.
  • Moretti Neto, Rafael Tobias; Federal University of Alfenas. Dental School. Department of Clinics and Surgery. Alfenas. BR
  • Hiramatsu, Daniel Afonso; s.af
  • Suedam, Valdey; s.af
  • Conti, Paulo César Rodrigues; University of São Paulo. Bauru School of Dentistry. Department of Prosthodontics. Bauru. BR
  • Rubo, José Henrique; University of São Paulo. Bauru School of Dentistry. Department of Prosthodontics. Bauru. BR
J. appl. oral sci ; 19(1): 47-51, Jan.-Feb. 2011. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-578747
ABSTRACT
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Poliuretanos / Implantes Dentários / Planejamento de Prótese Dentária / Prótese Dentária Fixada por Implante Tipo de estudo: Estudo prognóstico Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Federal University of Alfenas/BR / University of São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Poliuretanos / Implantes Dentários / Planejamento de Prótese Dentária / Prótese Dentária Fixada por Implante Tipo de estudo: Estudo prognóstico Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Federal University of Alfenas/BR / University of São Paulo/BR