Your browser doesn't support javascript.
loading
Punção com agulha de Veress no hipocôndrio esquerdo para a criação do pneumoperitônio: valor diagnóstico das provas de posicionamento da agulha em pacientes não selecionados / Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients
Becker Junior, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; Azevedo, Otávio Cansanção de; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes.
  • Becker Junior, Otávio Monteiro; s.af
  • Azevedo, João Luiz Moreira Coutinho; Universidade Federal de São Paulo. Departamento de Cirurgia. BR
  • Azevedo, Otávio Cansanção de; s.af
  • Hypólito, Octávio Henrique Mendes; s.af
  • Miyahira, Susana Abe; Universidade Federal de São Paulo. Curso de Doutorado. BR
  • Miguel, Gustavo Peixoto Soares; Universidade Federal do Espirito Santo. Departamento de Cirurgia. BR
  • Machado, Afonso Cesar Cabral Guedes; Universidade Federal de São Paulo. BR
Rev. Col. Bras. Cir ; 38(1): 28-34, jan.-fev. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-584124
RESUMO
OBJETIVO: Verificar a eficiência da punção com agulha de Veress no hipocôndrio esquerdo, a acurácia dos testes descritos para o correto posicionamento intraperitoneal da ponta da agulha de Veress em população não selecionada. MÉTODOS: Noventa e um pacientes, sem quaisquer critérios de exclusão, consecutivamente agendados para procedimentos videolaparoscópicos, tiveram a parede abdominal puncionada no hipocôndrio esquerdo. Os pacientes receberam anestesia geral e ventilação controlada mecânica segundo o protocolo. Após a punção foram utilizadas cinco provas para testar o posicionamento da ponta da agulha no interior da cavidade peritoneal: prova da aspiração - PA, da resistência à infusão - Pres, da recuperação do líquido infundido - Prec, prova do gotejamento - PG, e a prova da pressão intraperitoneal inicial - PPII. Os resultados foram considerados para cálculo da sensibilidade (S) e da especificidade (E) e valores preditivos positivos (VPP) e valores preditivos negativos (VPN). Métodos inferenciais estatísticos foram utilizados na análise dos achados. RESULTADOS: Ocorreram 13 fracassos. A PA teve E=100 por cento e VPN=100 por cento. Pres teve S=100 por cento; E=0; VPP=85,71 por cento VPN= não se aplica. Prec: S=100 por cento; E= 53,84 por cento; VPP= 92,85 por cento; VPN= 100 por cento. PG: S=100 por cento; E= 61,53 por cento; VPP= 93,97 por cento VPN= 100 por cento. Na PPII, a S, E, VPP e VPN foram de 100 por cento. CONCLUSÃO: A punção no hipocôndrio esquerdo é eficiente, as provas realizadas orientam o cirurgião a despeito do gênero, IMC ou operações prévias.
ABSTRACT
Objective: To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Methods: Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test - AT; resistance to infusion - Pres; recovery of the infused fluid - Prec, dripping test - DT, and test of initial intraperitoneal pressure - IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. Results: There were 13 failures. AT had E = 100 percent and NPV 100 percent. Pres had S = 100 percent, E = 0; PPV = 85.71 percent; NPV does not apply. Prec: S = 100 percent, E = 53.84 percent, PPV = 92.85 percent, NPV = 100 percent. DT: S = 100 percent, E = 61.53 percent, PPV = 93.97 percent NPV 100 percent. In IIPP, S, E, PPV and NPV were 100 percent. Conclusion: The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Pneumoperitônio Artificial / Agulhas Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica / Estudo prognóstico Limite: Adolescente / Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. Col. Bras. Cir Assunto da revista: Cirurgia Geral Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade Federal do Espirito Santo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Pneumoperitônio Artificial / Agulhas Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica / Estudo prognóstico Limite: Adolescente / Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. Col. Bras. Cir Assunto da revista: Cirurgia Geral Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade Federal do Espirito Santo/BR