Your browser doesn't support javascript.
loading
Comparação das medidas de pressão arterial no consultório, no domicílio e pela monitorização ambulatorial da pressão arterial (MAPA) em crianças com hipertensão arterial / Comparison of blood pressure measurement in the office, at home and ambulatory blood pressure (ABP) in children with arterial hypertension
São Paulo; s.n; 2008. [101] p. tab, graf.
Tese em Português | LILACS | ID: lil-587294
RESUMO
O diagnóstico e acompanhamento da hipertensão arterial (HA) no paciente pediátrico dependem da acurácia e da representatividade da medida da pressão arterial (PA). A monitorização ambulatorial da pressão arterial (MAPA), apesar de suas vantagens em relação à medida casual, apresenta custo elevado e pode trazer desconforto ao paciente. A medida residencial da pressão arterial (MRPA), apesar de pouco estudada na criança, apresenta-se como um alternativo potencial à MAPA. Os objetivos deste estudo foram comparar as medidas da PA aferidas no consultório, na MRPA, na Liga de Hipertensão e pela MAPA avaliando o efeito do ambiente/observador e determinando a freqüência de valores compatíveis com HA nessas 4 situações. Este estudo foi transversal,prospectivo e foram incluídos pacientes com HA e PA controlada ou não no consultório. Foram analisadas as médias das pressões arteriais sistólicas e diastólicas. A MRPA foi realizada com aparelho OMRON HEM 705 CP por 14 dias, em dois períodos (manhã ou tarde e noite). Na véspera do início da MRPA, o paciente compareceu à Liga de Hipertensão do HC-FMUSP para colocação do equipamento da MAPA (SPACELABS 90207). Foram analisados os dados de 40 pacientes (14 meninas e 26 meninos), idade média 12,1±3,6 anos. Não houve diferença estatística entre as médias das pressões sistólicas (ANOVA p=0,3100) e diastólicas (ANOVA p=0,7700) no consultório com as médias diurnas da MRPA e nem com as médias sistólicas (ANOVA p=0,8240) e diastólicas(ANOVA p=0,1530) do período noturno da MRPA. As médias das pressões sistólicas e diastólicas da Liga e da MAPA foram maiores do que as médias do consultório e da MRPA (p<0,001), porém não houve diferença estatística entre as médias sistólicas e diastólicas da Liga com a MAPA (p=0,077) e (p=0,962) respectivamente. As médias das pressões diastólicas da MRPA foram menores do que as médias do consultório (p=0,001). Em relação à freqüência de pacientes com PA não controlada, esta foi maior na...
ABSTRACT
The diagnosis and monitoring of hypertension in pediatric patients depend on the accuracy and reproducibility of blood pressure (BP) measurement. Ambulatory blood pressure monitoring (ABPM), despite its advantages over office BP, is costly and can cause discomfort to the patient. The blood pressure measured at home (HBP), although poorly studied in children, represents a potential alternative to ABPM. The objectives of this study were to compare BP measurement in four clinical conditions office BP , casual BP measured at Liga de Hipertensão, HBP and ABPM, evaluate the effect of environment / observer and to determine the frequency of BP values compatible with the diagnosis of hypertension. This study was cross-sectional and prospective and included patients with arterial hypertension with/without properly controlled BP in the office. The means of systolic and diastolic BP were analyzed in the 4 clinical conditions. HBP was measured for 14 days using a validated fully automatic Omron HEM 705 CP device. ABPM was measured with SpaceLabs 90207 non-invasive portable oscilometric device. We analyzed data from 40 patients (14 girls and 26 boys), mean age 12.1 ± 3.6 (SD) years. There was no difference between systolic (ANOVA p = 0.3100) and diastolic (ANOVA p= 0.7700) BP in the office and daytime HBP nor with nightime systolic HBP ( ANOVA p = 0.8240) and diastolic HBP(ANOVA p = 0.1530). The average systolic and diastolic BP at the Liga de Hipertensão and ABPM were higher than office and HB P (p <0001), but there was no difference in the average systolic (p= 0.077) and diastolic (p = 0.962) BP between Liga and ABPM. The diastolic HBP was lower than office diastolic BP (p = 0001). The frequency of BP values compatible with hipertension was higher at the Liga de Hipertensão (Mc Nemar p <0005), while comparisons between officedaytime HBP, office- daytime ABPM and daytime HBP-ABPM were not significant (Mc Nemar p> 0.05). The BP measurements during nightime ABPM...
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Criança / Adolescente / Monitorização Ambulatorial da Pressão Arterial / Pressão Arterial / Hipertensão Limite: Adolescente / Criança / Feminino / Humanos / Masculino Idioma: Português Ano de publicação: 2008 Tipo de documento: Tese

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Criança / Adolescente / Monitorização Ambulatorial da Pressão Arterial / Pressão Arterial / Hipertensão Limite: Adolescente / Criança / Feminino / Humanos / Masculino Idioma: Português Ano de publicação: 2008 Tipo de documento: Tese