Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests
Miyashiro, Mariane; Suedam, Valdey; Moretti Neto, Rafael Tobias; Ferreira, Paulo Martins; Rubo, José Henrique.
  • Miyashiro, Mariane; University of São Paulo. Bauru School of Dentistry. Bauru. BR
  • Suedam, Valdey; University of São Paulo. Bauru School of Dentistry. Department of Prosthodontics. Bauru. BR
  • Moretti Neto, Rafael Tobias; University of São Paulo. Bauru School of Dentistry. Department of Prosthodontics. Bauru. BR
  • Ferreira, Paulo Martins; University of São Paulo. Bauru School of Dentistry. Department of Prosthodontics. Bauru. BR
  • Rubo, José Henrique; University of São Paulo. Bauru School of Dentistry. Department of Prosthodontics. Bauru. BR
J. appl. oral sci ; 19(3): 244-248, May-June 2011. ilus, graf
Artigo em Inglês | LILACS | ID: lil-588130
ABSTRACT
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Poliuretanos / Implantes Dentários / Prótese Dentária Fixada por Implante / Módulo de Elasticidade Limite: Humanos Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: University of São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Poliuretanos / Implantes Dentários / Prótese Dentária Fixada por Implante / Módulo de Elasticidade Limite: Humanos Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: University of São Paulo/BR