Your browser doesn't support javascript.
loading
Quality of water sources used as drinking water in a Brazilian peri-urban area
Razzolini, Maria Tereza Pepe; Günther, Wanda Maria Risso; Peternella, Francisca Alzira dos Santos; Martone-Rocha, Solange; Bastos, Veridiana Karmann; Santos, Thaís Filomena da Silva; Cardoso, Maria Regina Alves.
  • Razzolini, Maria Tereza Pepe; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
  • Günther, Wanda Maria Risso; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
  • Peternella, Francisca Alzira dos Santos; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
  • Martone-Rocha, Solange; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
  • Bastos, Veridiana Karmann; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
  • Santos, Thaís Filomena da Silva; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
  • Cardoso, Maria Regina Alves; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
Braz. j. microbiol ; 42(2): 560-566, Apr.-June 2011. graf, tab
Artigo em Inglês | LILACS | ID: lil-590003
ABSTRACT
The objective of this paper was to assess bacteriological quality of drinking water in a peri-urban area located in the Metropolitan Region of São Paulo, Brazil. A total of 89 water samples were collected from community plastic tanks and 177 water samples from wells were collected bimonthly, from September 2007 to November 2008, for evaluating bacteriological parameters including Escherichia coli, Enterococcus and heterotrophic plate count (HPC). Clostridium perfringens was investigated in a subsample (40 samples from community plastic tank and 40 from wells). E. coli was present in 5 (5.6 percent) samples from community plastic tanks (2.0 - 5.1x10(4) MPN/100mL) and in 70 (39.5 percent) well samples (2.0 - 8.6x10(4) MPN/100mL). Thus, these samples were not in accordance with the Brazilian Regulation. Enterococcus was detected in 20 (22.5 percent) samples of the community plastic tanks (1 to 79 NC/100mL) and in 142 (80.2 percent) well samples (1 to >200 NC/100mL). C. perfringens was detected in 5 (12.5 percent) community plastic tanks samples and in 35 (87.5 percent) wells samples (2.2 to >16 MPN/100mL). HPC were above 500 CFU/mL in 5 (5.6 percent) waters from community plastic tanks. In wells samples, the HPC ranged from <1 to 1.6x10(4) CFU/mL. The residual chlorine did not attend the standard established in the drinking water legislation (0.2 mg/L), except in 20 (22.5 percent) samples. These results confirm the vulnerability of the water supply systems in this peri-urban area what is clearly a public health concern.


Texto completo: DisponíveL Índice: LILACS (Américas) País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Braz. j. microbiol Assunto da revista: Microbiologia Ano de publicação: 2011 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Braz. j. microbiol Assunto da revista: Microbiologia Ano de publicação: 2011 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR