Your browser doesn't support javascript.
loading
Avaliação das características geométricas, dimensionais, de flexibilidade e resistência torcional dos instrumentos de NiTi do sistema pro taper universal para retratamento / Evaluation of dimensional and geometry features, flexibility and torsional resistance of NiTi pro tapper universal retreatment system instruments
Araraquara; s.n; 2009. 119 p. ilus.
Tese em Português | LILACS, BBO | ID: lil-590717
RESUMO
O presente trabalho se propôs a avaliar as características geométricas e dimensionais dos instrumentos de NiTi do sistema ProTaper Universal Retratamento bem como sua flexibilidade e resistência torcional. Um total de 102 instrumentos foram empregados neste estudo. Inicialmente, 12 instrumentos de cada formato foram submetidos a uma caracterização geométrica e dimensional por microscopia óptica. Foram avaliados os parâmetros ângulo, comprimento e diâmetro de ponta, comprimento de cada pitch ao longo das hastes e diâmetro do instrumento a cada milímetro da ponta. Após isto, todos os instrumentos foram aleatoriamente divididos em 3 grupos distintos Grupo 1 contendo 36 instrumentos ProTaper Universal Retratamento D1, D2 e D3, sendo 12 unidades de cada formato para os ensaios de torção; Grupo 2 contendo 36 instrumentos ProTaper Universal Retratamento D1, D2 e D3, sendo 12 unidades de cada formato para os ensaios de flexibilidade; Grupo 3 contendo 30 instrumentos ProTaper Universal Retratamento D1, D2 e D3, sendo 10 unidades de cada formato para os ensaios de torção após estes instrumentos terem sido usados na desobturação de 15 canais radiculares. Tais ensaios de torção e flexibilidade foram executados de acordo com a especificação ISO 3630-1 em um dispositivo de bancada para testes utilizando um programa para aquisição e processamento dos dados especialmente desenvolvido para este fim. Os valores para torque máximo, deflexão angular até a fratura e momento de dobramento foram analisados estatisticamente pelo teste t de Student. Os resultados demonstraram que os instrumentos do Sistema ProTaper Universal Retratamento apresentaram boa padronização geométrica e características de superfície aceitáveis, embora tenham sido verificadas diferenças geométricas e dimensionais entre os instrumentos do sistema. O torque máximo e o momento de dobramento a 45o foram...
ABSTRACT
The present study has proposed to evaluate the geometric and dimensional features of NiTi ProTaper Universal Retreatment System’s instruments as well as their flexibility and torsional resistance. It was used a total amount of 102 instruments. At the beginning, 12 instruments of each size were analyzed dimensional and geometrically by optical microscopy under parameters of angle, length and tip diameter, pitch’s length along the blade and instrument’s diameter from tip until the end of the active part. After that, all the instruments were randomly divided into 3 different groups Group 1 having 36 ProTaper Universal Retreatment instruments inside (D1, D2 and D3),12 samples from each size, to be submitted to torsion test; Group 2 having 36 ProTaper Universal Retreatment instruments inside (D1, D2 and D3),12 samples from each size, to be submitted to bending test; Group 3 having 30 ProTaper Universal Retreatment instruments inside (D1, D2 and D3),10 samples from each size, to be submitted to torsion test after being used in 15 root canal unfilling. These torsion and bending tests were performed using a bench test device connected with a software to acquire and process data specially developed to this purpose, according to ISO 3630-1. Maximum torque, angular deflection until fracture and bending moment values were statistically analysed using Student’s t test. The results showed that ProTaper Universal Retreatment System’s instruments presented good geometric standardization and acceptable surface features, however differences were detected among the instruments. The maximum torque and the bending moment at 45º were higher for instruments with larger diameters (D1>D2>D3), even though angular deflection didn’t show this same relationship. Besides, the new instruments showed a higher maximum torque value when compared to the ones who were used in 15 root canals unfilling.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Retratamento / Torque / Endodontia Tipo de estudo: Ensaio Clínico Controlado Idioma: Português Ano de publicação: 2009 Tipo de documento: Tese

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Retratamento / Torque / Endodontia Tipo de estudo: Ensaio Clínico Controlado Idioma: Português Ano de publicação: 2009 Tipo de documento: Tese