Your browser doesn't support javascript.
loading
Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease
Abreu Filho, Luciano Maurício de; Forte, Antonio Artur da Cruz; Sumita, Marcos Kiyoshi; Favarato, Desidério; Meireles, George Cesar Ximenes.
  • Abreu Filho, Luciano Maurício de; Hospital Stella Maris. Guarulhos. BR
  • Forte, Antonio Artur da Cruz; Hospital Stella Maris. Guarulhos. BR
  • Sumita, Marcos Kiyoshi; Hospital Stella Maris. Guarulhos. BR
  • Favarato, Desidério; Universidade de São Paulo. Instituto do Coração. São Paulo. BR
  • Meireles, George Cesar Ximenes; Instituto de Assistência Médica ao Servidor Público Estadual. São Paulo. BR
Clinics ; 66(6): 985-989, 2011. tab
Artigo em Inglês | LILACS | ID: lil-594366
ABSTRACT

BACKGROUND:

In Brazil, despite the recommendations of the Brazilian Society of Hemodynamics and Interventional Cardiology, the National Health System has not yet approved the use of drug-eluting stents. In percutaneous coronary interventions performed in the public and part of the private health care system, bare metal stents are used as the only option. Therefore, new information on bare metal stents is of great importance. The primary endpoint was to evaluate the influence of the alloy and the profile of coronary stents on late loss and restenosis rates 6 months after implantation in patients with multivessel coronary disease.

METHODS:

Single center, randomized and prospective study comparison of cobalt-chromium versus stainless steel stent implantation in 187 patients with multivessel coronary disease. At least one cobalt-chromium and one stainless steel stent were implanted per patient.

RESULTS:

Mean age of patients was 59.5 + 10.1 years with a prevalence of males (66.3 percent) and patients with acute coronary syndrome (56 percent). Baseline clinical characteristics were similar with hypertension in 146 (78 percent), dyslipidemia in 85 (45.5 percent) and diabetes in 68 (36.4 percent). Two hundred and twenty-nine cobalt-chromium and 284 stainless steel stents were implanted. Angiographic variables showed no statistically significant difference. Angiographic follow-up to 6 months after implantation showed similar late loss and restenosis rates.

CONCLUSION:

The use of two different alloys, stainless steel and cobalt-chrome stents, in the same patient and in the same vessel produced similar 6-month restenosis and late loss rates.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aço Inoxidável / Doença da Artéria Coronariana / Stents / Ligas de Cromo / Reestenose Coronária Tipo de estudo: Ensaio Clínico Controlado / Estudo de etiologia / Guia de Prática Clínica / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Stella Maris/BR / Instituto de Assistência Médica ao Servidor Público Estadual/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aço Inoxidável / Doença da Artéria Coronariana / Stents / Ligas de Cromo / Reestenose Coronária Tipo de estudo: Ensaio Clínico Controlado / Estudo de etiologia / Guia de Prática Clínica / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Stella Maris/BR / Instituto de Assistência Médica ao Servidor Público Estadual/BR / Universidade de São Paulo/BR