Is miniscrew primary stability influenced by bone density?
Marquezan, Mariana; Souza, Margareth Maria Gomes de; Araújo, Mônica Tirre de Souza; Nojima, Lincoln Issamu; Nojima, Matilde da Cunha Gonçalves.
  • Marquezan, Mariana; Federal University of Rio de Janeiro. Pedodontics and Orthodontics Department. Rio de Janeiro. BR
  • Souza, Margareth Maria Gomes de; Federal University of Rio de Janeiro. Pedodontics and Orthodontics Department. Rio de Janeiro. BR
  • Araújo, Mônica Tirre de Souza; Federal University of Rio de Janeiro. Pedodontics and Orthodontics Department. Rio de Janeiro. BR
  • Nojima, Lincoln Issamu; Federal University of Rio de Janeiro. Pedodontics and Orthodontics Department. Rio de Janeiro. BR
  • Nojima, Matilde da Cunha Gonçalves; Federal University of Rio de Janeiro. Pedodontics and Orthodontics Department. Rio de Janeiro. BR
Braz. oral res ; 25(5): 427-432, Sept.-Oct. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-601882
ABSTRACT
Primary stability is absence of mobility in the bone bed after mini-implant placement and depends on bone quality among other factors. Bone quality is a subjective term frequently considered as bone density. The aim of this preliminary study was to evaluate bone density in two bovine pelvic regions and verify the primary stability of miniscrews inserted into them. Forty bone blocks were extracted from bovine pelvic bones, 20 from iliac and 20 from pubic bone, all of them containing cortical bone about 1 mm thick. Half of the sections extracted from each bone were designated for histological evaluation of bone density (trabecular bone area - TBA) and the other half for bone mineral density (BMD) evaluation by means of central dual-energy X-ray absorptiometry (DEXA). Then, twenty self-drilling miniscrews (INPÒ, São Paulo, Brazil) 1.4 mm in diameter and 6 mm long were inserted into the bone blocks used for BMD evaluation. Peak implant insertion torque (IT) and pull-out strength (PS) were used for primary stability evaluation. It was found that iliac and pubic bones present different bone densities, iliac bone being less dense considering BMD and TBA values (P > 0.05). However, the miniscrew primary stability was not different when varying the bone type (P < 0.05). IT and PS were not influenced by these differences in bone density when cortical thickness was about 1 mm thick.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Parafusos Ósseos / Densidade Óssea / Implantes Dentários / Procedimentos de Ancoragem Ortodôntica Limite: Animais Idioma: Inglês Revista: Braz. oral res Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Rio de Janeiro/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Parafusos Ósseos / Densidade Óssea / Implantes Dentários / Procedimentos de Ancoragem Ortodôntica Limite: Animais Idioma: Inglês Revista: Braz. oral res Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Rio de Janeiro/BR