Your browser doesn't support javascript.
loading
Comparação entre os métodos direto e indireto de determinação do consumo máximo de oxigênio em mulheres corredoras / Comparison between direct and indirect methods for the determination of the maximal oxygen uptake in female runners
Peserico, Cecília Segabinazi; Mezzaroba, Paulo Victor; Nogueira, Geraldo Angelo; Moraes, Solange Marta Franzói de; Machado, Fabiana Andrade.
  • Peserico, Cecília Segabinazi; Universidade Estadual de Maringá. BR
  • Mezzaroba, Paulo Victor; Universidade Estadual de Maringá. BR
  • Nogueira, Geraldo Angelo; Universidade Estadual de Maringá. BR
  • Moraes, Solange Marta Franzói de; Universidade Estadual de Maringá. BR
  • Machado, Fabiana Andrade; Universidade Estadual de Maringá. BR
Rev. bras. med. esporte ; 17(4): 270-273, jul.-ago. 2011. tab
Artigo em Português | LILACS | ID: lil-602331
RESUMO
O objetivo deste estudo foi comparar os valores de revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx determinados diretamente por um sistema de ergoespirometria com os valores preditos indiretamente pelo sistema ErgoPC durante um teste de esforço máximo realizado por mulheres corredoras. Participaram 20 mulheres corredoras treinadas (42,7 ± 6,4 anos; 1,64 ± 0,04m; 58,3 ± 5,8kg; IMC 21,7 ± 1,9kg/m² e 22,3 ± 3,5 por centoG). Os sujeitos foram submetidos à avaliação da composição corporal e a um teste de esforço progressivo em esteira ergométrica (Inbrasport, Porto Alegre, RS, Brasil) para mensuração da aptidão aeróbia (revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx). A velocidade inicial foi de 7km/h com incrementos de 1km/h a cada três minutos, sendo mantida uma inclinação constante durante todo o teste equivalente a 1 por cento. As participantes foram fortemente estimuladas a permanecerem no teste o maior tempo possível, até a exaustão voluntária. Para a mensuração direta do revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx, foi utilizado um sistema de ergoespirometria de circuito aberto (analisador de gases Espirômetro revistas/rbme/v17n4/a12cr01.jpg" />2000 Inbrasport, Porto Alegre, Brasil). A predição indireta do revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx foi realizada através do programa ErgoPC que utiliza a fórmula de Foster (1996) para tal predição. Para a análise estatística, foi realizado o teste t de Student (p < 0,05), para a comparação dos valores de revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx obtidos de forma direta e indireta, e o teste de correlação de Pearson, para correlacionar essas duas variáveis. A medida direta do revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx apresentou valor de 51,8 ± 6,8ml/kg/min, e o indireto, 42,8 ± 3,7ml/kg/min. Na comparação entre os dois resultados foi encontrada diferença estatisticamente significante entre as variáveis. A correlação encontrada entre os valores de revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx foi de r = 0,67. Portanto, os resultados mostram que o revistas/rbme/v17n4/a12cr01.jpg" align="absmiddle" />2máx obtido de forma indireta subestima o valor da medida direta.
ABSTRACT
The aim of this study was to compare the values of 2max directly determined by an ergospirometry system, with values indirectly predicted by the ErgoPC system during maximal exercise test underwent by female runners. Twenty trained female runners participated in the study (42.7 ± 6.4 years-old, height 1.64 ± 0.04m, body mass 58.3 ± 5.8kg, body mass index (BMI) 21.7 ± 1.9kg/m² and body fat percentage 22.3 ± 3.5. The subjects were evaluated for body composition and underwent a progressive exercise test on treadmill (Inbrasport, Porto Alegre, RS, Brazil) to measure the aerobic fitness (2max ). The initial speed was 7km/h with increments of 1km/h every three minutes and constant inclination of 1 percent was kept throughout the test. The participants were encouraged to remain in the test as long as possible until voluntary exhaustion. The gas analyzer VO2000 Inbrasport Spirometer, Porto Alegre, Brazil was used for the direct measurement of 2max , while for the indirect measurement of 2max the ErgoPC program with the prediction formula from Foster (1996) was used. Statistical analysis was performed by Student's t test for the comparison of the values of 2max obtained in the direct and indirect test, and Pearson's correlation was applied to correlate these two variables. Direct measurement of 2max showed a value of 51.8 ± 6.8ml/kg/min and indirect one of 42.8 ± 3.7ml/kg/min. The comparison between both results was significantly different. The correlation between the values of 2max was r = 0.67. Thus, the results show that the obtained 2max by an indirect way underestimates the value of the direct measurement.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Consumo de Oxigênio / Espirometria / Aptidão Física / Teste de Esforço Tipo de estudo: Estudo prognóstico Limite: Adulto / Feminino / Humanos Idioma: Português Revista: Rev. bras. med. esporte Assunto da revista: Medicina Esportiva Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Maringá/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Consumo de Oxigênio / Espirometria / Aptidão Física / Teste de Esforço Tipo de estudo: Estudo prognóstico Limite: Adulto / Feminino / Humanos Idioma: Português Revista: Rev. bras. med. esporte Assunto da revista: Medicina Esportiva Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Maringá/BR