Your browser doesn't support javascript.
loading
Exposição ocupacional de fisioterapeutas aos campos elétrico e magnético e a eficácia das gaiolas de Faraday / Occupational exposure of physical therapists to electric and magnetic fields and the efficacy of Faraday cages
Messias, Iracimara de Anchieta; Okuno, Emico; Colacioppo, Sérgio.
  • Messias, Iracimara de Anchieta; Universidade Estadual Paulista. Faculdade de Ciências e Tecnologia. Presidente Prudente. BR
  • Okuno, Emico; Universidade de São Paulo. Instituto de Física. São Paulo. BR
  • Colacioppo, Sérgio; Universidade de São Paulo. Faculdade de Saúde Pública. São Paulo. BR
Rev. panam. salud pública ; 30(4): 309-316, oct. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-606844
RESUMO
OBJETIVO: Medir a exposição de fisioterapeutas aos campos elétrico e magnético produzidos por 17 equipamentos de diatermia de ondas curtas (DOC) de clínicas de fisioterapia da cidade de Presidente Prudente, São Paulo, Brasil. Comparar os valores medidos com os níveis de exposição recomendados pelo ICNIRP (International Commission on Non-Ionizing Radiation Protection). Observar a eficácia das gaiolas de Faraday como medida de proteção à exposição dos fisioterapeutas aos campos elétrico e magnético oscilantes. MÉTODOS: As medidas dos campos elétrico e magnético foram realizadas durante sessões reais de tratamento fisioterápico, em quatro pontos: nas proximidades da pelve e da cabeça do operador, dos cabos elétricos dos aparelhos e dos eletrodos de aplicação. O equipamento de medição utilizado foi o EMR-200 da Wandell & Goltermann. RESULTADOS: Os valores obtidos nas proximidades dos eletrodos e cabos estavam de 10 a 30 vezes acima dos níveis de referência ocupacionais recomendados pela ICNIRP. Nas salas de tratamento com DOC com gaiola de Faraday, os campos encontrados foram ainda mais altos que os das salas sem esse revestimento, principalmente o campo magnético, com valores superiores a 100 vezes o limite de exposição da ICNIRP. CONCLUSÕES: As intensidades dos campos elétrico e magnético obtidas neste trabalho estão, de modo geral, acima dos níveis de exposição recomendados pelas normas da ICNIRP. Além disso observou-se que a gaiola de Faraday não fornece proteção aos fisioterapeutas mas aumenta os níveis de exposição aos quais estão submetidos estes profissionais.
ABSTRACT
OBJECTIVE: Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields. METHODS: Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200. RESULTS: The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit. CONCLUSIONS: The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Radiação não Ionizante / Terapia por Ondas Curtas / Exposição Ocupacional / Modalidades de Fisioterapia / Campos Eletromagnéticos Tipo de estudo: Estudo de etiologia / Estudos de avaliação / Guia de Prática Clínica / Fatores de risco Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. panam. salud pública Assunto da revista: Saúde Pública Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual Paulista/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Radiação não Ionizante / Terapia por Ondas Curtas / Exposição Ocupacional / Modalidades de Fisioterapia / Campos Eletromagnéticos Tipo de estudo: Estudo de etiologia / Estudos de avaliação / Guia de Prática Clínica / Fatores de risco Limite: Humanos País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. panam. salud pública Assunto da revista: Saúde Pública Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual Paulista/BR / Universidade de São Paulo/BR