Your browser doesn't support javascript.
loading
Effect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching
Pita, Murillo Sucena; Ribeiro, Adriana Barbosa; Garcia, Alicio Rosalino; Pedrazzi, Vinicius; Zuim, Paulo Renato Junqueira.
  • Pita, Murillo Sucena; University of São Paulo. School of Dentistry of Ribeirão Preto. Department of Dental Materials and Prosthodontics. Ribeirão Preto. BR
  • Ribeiro, Adriana Barbosa; University of São Paulo. School of Dentistry of Ribeirão Preto. Department of Dental Materials and Prosthodontics. Ribeirão Preto. BR
  • Garcia, Alicio Rosalino; São Paulo State University. School of Dentistry of Araçatuba. Department of Dental Materials and Prosthodontics. Araçatuba. BR
  • Pedrazzi, Vinicius; University of São Paulo. School of Dentistry of Ribeirão Preto. Department of Dental Materials and Prosthodontics. Ribeirão Preto. BR
  • Zuim, Paulo Renato Junqueira; São Paulo State University. School of Dentistry of Araçatuba. Department of Dental Materials and Prosthodontics. Araçatuba. BR
Braz. oral res ; 25(6): 506-511, Nov.-Dec. 2011. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-608018
ABSTRACT
The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (µV). The results, which were assessed using analysis of variance (ANOVA) to a 5 percent significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Músculo Temporal / Placas Oclusais / Músculo Masseter Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. oral res Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Paulo State University/BR / University of São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Músculo Temporal / Placas Oclusais / Músculo Masseter Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. oral res Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: São Paulo State University/BR / University of São Paulo/BR