Análise da integridade e funcionalidade do nervo laríngeno recorrente após tireoidectomias: estudo comparativo com e sem a utilização da eletroneuromiografia intra-operatório / Analysis of the integrity and functionality of the recurrent laryngeal nerve after thyroidectomies- Comparative study with and without the use of intraoperative electroneuromyography
São Paulo; s.n; 2011. 225 p. ilus, tab.
Tese em Português | LILACS | ID: lil-609369
RESUMO
A intervenção cirúrgica sobre a glândula tireóide pode apresentar diversas complicações, sendo uma das mais temidas é a lesão dos nervos laríngeos recorrentes que leva a paresia ou paralisia da prega vocal em até 15% dos pacientes conforme registra a literatura. No entanto, muitas vezes os índices de lesão do nervo são subestimados, pois muitas vezes apenas pacientes com sintomas importantes são investigados, muitas vezes, no entanto, a preocupação com a lesão do nervo é crucial durante o ato cirúrgico, especialmente em dissecções bilaterais do nervo. Apesar dos enormes avanços tecnológicos dos últimos tempos, esta complicação apenas diminui, não desapareceu. Diversas técnicas de diagnóstico intra-operatório de viabilidade do nervo foram desenvolvidas nas últimas décadas, porém muitas delas de difícil execução prática, outras apresentam altos índices de complicações e outras ainda tem pouca especificidade no diagnóstico da lesão do nervo laríngeo recorrente. Uma das técnicas de maior aceitação é a monitorização intra-operatória não invasiva dos nervos laríngeos recorrentes através da utilização do eletrodo de superfície acoplado à cânula endotraqueal. Esta técnica apresenta diversas vantagens pois não estende o tempo cirúrgico, não há necessidade de modificação da técnica operatória ou anestésica e é de fácil utilização e assimilação pela equipe médica. No entanto muito se discute hoje na literatura sobre os reais benefícios desta tecnologia e qual o impacto na diminuição da lesão pósoperatória do nervo laríngeo recorrente. Assim foi estudado através de um estudo duplo-cego e randomizado a evolução de pacientes submetidos à tireoidectomia com e sem a utilização da monitorização intra-operatória do nervo laríngeo recorrente. Para tal análise avaliamos e comparamos os resultados pré e pós operatório dos parâmetros de mobilidade das pregas vocais (através da laringoscopia direta) e função (através da análise vocal auditiva e acústica), além do tempo...
ABSTRACT
The surgery of the thyroid gland could present several complications, one of the most feared is the recurrent laryngeal nerve injury leading to vocal fold paresy or paralysis up to 15% of patients according to literature. However, many times the rate of nerve injury are underestimated because frequently only patients with significant symptoms are investigated, often however the concern about the nerve injury is crucial during surgery, especially in bilateral dissections of the nerve. Despite enormous technological advances of recent times, this kind of complication only diminishes, not disappeared. Several techniques of intraoperative nerve viability have been developed in recent decades, but many of them are difficult to implement, others have high rates of complications and still others have little specificity in the diagnosis of recurrent laryngeal nerve injury. One of the most accepted techniques for nerve evaluation is the noninvasive intraoperative monitoring by using surface electrodes attached to the endotracheal tube. This approach has several advantages because it no extends the operating time, no need modification of surgical or anesthetic technique and is easy to use and be assimilated by the surgical team. However there is no consensus in the literature about the real benefits of this technology and what is its impact on the reduction of postoperative injury of the recurrent laryngeal nerve. It was evaluated by a double-blind, randomized study of patients underwent thyroidectomies with and without the use of intraoperative monitoring sistem of recurrent laryngeal nerve. For this analysis we evaluated and compared the results of preoperative and postoperative parameters of vocal fold mobility (by direct laryngoscopy) and function (through vocal and and acoustic analysis), the time spent in identifying the recurrent laryngeal nerve during surgery was also compared. The patients were operated by the same surgeon and by the same surgical...
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Nervo Laríngeo Recorrente / Tireoidectomia / Distúrbios da Voz / Eletromiografia Tipo de estudo: Ensaio Clínico Controlado Limite: Humanos Idioma: Português Ano de publicação: 2011 Tipo de documento: Tese

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Nervo Laríngeo Recorrente / Tireoidectomia / Distúrbios da Voz / Eletromiografia Tipo de estudo: Ensaio Clínico Controlado Limite: Humanos Idioma: Português Ano de publicação: 2011 Tipo de documento: Tese