RESUMEN

Objetivo:

se propone una nueva metodología para estimar loscoeficientes de absorción de ruido mediante algoritmos genéticos.

Metodología:

se generan ondas sonoras que se hacen pasar a lo largo de un silenciador rectangular, atenuadas porel material absorbente dispuesto en las paredes. Con el nivel de presión sonora atenuación. Se hace una búsqueda, mediante algoritmos genéticos, de los parámetros de expresiones de atenuación propuestas que incluyen factores geométricos, longitud de onda y coeficiente de absorción.

Resultados:

seobtuvieron diferentes modelos matemáticos ajustados que permitenestimar los coeficientes de absorción a partir de características de un silenciador rectangular usado para medir su atenuación.

Conclusiones:

esta metodología permite obtener de forma simple y a bajo costo los coeficientes de absorción para nuevos materiales, que aunque pudieran diferir ligeramentecon los obtenidos con otras metodologías, permiten brindarsoluciones dentro de los rangos de precisión de la ingeniería aplicados en el diseño de sistemas de control de ruido.
ABSTRACT

Objective:

the authors propose a new methodology for estimating sound absorption coefficients using genetic algorithms.

Methodology:

sound waves are generated and conducted along a rectangular silencer. The waves are thenattenuated by the absorbing material covering the silencer’s walls. The attenuated sound pressure level is used in a genetic algorithm-based search to find the parameters of the proposed attenuation expressions that include geometric factors, the wavelength and the absorption coefficient.

Results:

a variety of adjusted mathematical models were found that make it possible to estimate the absorption coefficientsbased on the characteristics of a rectangular silencer used for measuring the attenuation of the noise thatpasses through it.

Conclusions:

this methodology makes it possible to obtain the absorption coefficients of new materials in a cheap and simple manner. Although these coefficients might be slightly different from those obtainedthrough other methodologies, they provide solutions within the engineering accuracy ranges that are used for designing noise control systems.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Som / Ruído Tipo de estudo: Estudo prognóstico Idioma: Espanhol Revista: Rev. Fac. Nac. Salud Pública Assunto da revista: Saúde Pública Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad de Antioquia/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Som / Ruído Tipo de estudo: Estudo prognóstico Idioma: Espanhol Revista: Rev. Fac. Nac. Salud Pública Assunto da revista: Saúde Pública Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad de Antioquia/CO