OBJETIVO:

avaliar in vitro e comparar a redução de intensidade das forças liberadas por três grupos de elásticos em cadeia, com diferentes configurações, de um mesmo fabricante, medidas em intervalos de tempo preestabelecidos.

MÉTODOS:

os segmentos de elásticos em cadeia foram alongados e mantidos ativados durante o experimento com o auxílio de um dispositivo desenvolvido especialmente para esse fim e para possibilitar a leitura das forças. A avaliação da degradação da força foi realizada medindo-se a intensidade da força ao longo do tempo, e calculando-se o percentual de força perdida em relação à força inicial, em cada intervalo de tempo e para cada amostra testada. RESULTADOS E

CONCLUSÕES:

os dados coletados foram submetidos a análises estatísticas e os resultados demonstraram que, nos momentos seguintes ao inicial, a intensidade da força variou, dentro dos grupos e entre os grupos, nos diferentes momentos. A leitura dos valores das forças remanescentes em cada momento, comparada à referência da força inicial, resultou em valores diferentes, com significância estatística, em todas as comparações efetuadas dentro de cada grupo de elásticos (curto, médio, longo). Após a análise dos resultados das comparações entre os grupos de elásticos em cadeia, conclui-se que, apesar de verificados alguns resultados estatisticamente significativos para a comparação das magnitudes das forças liberadas em cada momento, essas diferenças parecem não ter expressão clínica, demonstrando que, aparentemente, o espaçamento entre os elos não representa uma característica clinicamente significativa na degradação da força ao longo do tempo.
ABSTRACT

OBJECTIVE:

To evaluate and compare, in vitro, the decrease in the forces delivered in three groups of elastomeric chains, produced by the same manufacturer, according to the distance between links (short, medium, long).

METHODS:

The segments of elastomeric chains were stretched and kept activated during the trial using a device developed especially for this purpose, which also allowed force readings. Force degradation was evaluated by measuring force along time and calculating the percentage of force decrease from initial force at each time interval and for each specimen under test. RESULTS AND

CONCLUSIONS:

Data were statistically analyzed and results showed that at the different time points after initial readings, force intensity varied within and between groups. Readings of remaining forces at each time moment compared with the initial reference force revealed statistically significant differences in all the comparisons in each group of elastics (short, medium, long). Although the comparisons between forces delivered at each time point revealed statistically significant differences, these differences do not seem to have a clinical significance. The space between links does not seem to be a clinically significant characteristic in force degradation along time.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aparelhos Ortodônticos / Elastômeros / Materiais Dentários Idioma: Português Revista: Dental press j. orthod. (Impr.) Assunto da revista: Ortodontia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UFRJ/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aparelhos Ortodônticos / Elastômeros / Materiais Dentários Idioma: Português Revista: Dental press j. orthod. (Impr.) Assunto da revista: Ortodontia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UFRJ/BR