"Non Working Beating Heart": novo método de proteção miocárdica no transplante cardíaco / Non Working Beating Heart: a new strategy of myocardial protection during heart transplant
Dinkhuysen, Jarbas Jakson; Contreras, Carlos; Cipullo, Reginaldo; Finger, Marco Aurélio; Rossi, João; Manrique, Ricardo; Magalhães, Hélio M; Chaccur, Paulo.
  • Dinkhuysen, Jarbas Jakson; Universidade de São Paulo. Faculdade de Medicina.
  • Contreras, Carlos; IDPC. São Paulo. BR
  • Cipullo, Reginaldo; IDPC. São Paulo. BR
  • Finger, Marco Aurélio; IDPC. São Paulo. BR
  • Rossi, João; IDPC. São Paulo. BR
  • Manrique, Ricardo; IDPC. São Paulo. BR
  • Magalhães, Hélio M; IDPC. São Paulo. BR
  • Chaccur, Paulo; IDPC. São Paulo. BR
Rev. bras. cir. cardiovasc ; 26(4): 630-634, out.-dez. 2011. ilus
Artigo em Português | LILACS | ID: lil-614757
RESUMO
INTRODUÇÃO E

OBJETIVO:

Trata-se do implante em posição ortotópica bicaval bipulmonar do coração doado batendo em normotermia. Este estudo busca diminuir o tempo isquêmico e criar condições de ir se adaptando ao organismo hospedeiro.

MÉTODOS:

Já em CEC, a primeira anastomose a ser feita é a da aorta, reperfundindo as artérias coronárias e recuperando os batimentos. As restantes são realizadas com o coração batendo em ritmo sinusal, sendo a da artéria pulmonar a última. Esta metodologia foi aplicada em 10 pacientes receptores, sendo oito do sexo masculino, com idades entre 16 e 69 (média de 32,7 anos), PSAo 90-100 (média de 96 mmHg), PSAP 25-65 (média de 46,1 mmHg), RVP 0,9-5,0 (média de 3,17 Wood), GTP 4-13 (média de 7,9 mmHg). Entre os 10 doadores, sete eram do sexo masculino, com idade entre 15 e 48 (média 27,7 anos), peso entre 65 e 114 kg (média de 83,1 kg). As causas do coma encefálico foram TCE (cinco), AVCH (quarto) e tumor cerebral (um).

RESULTADOS:

O tempo isquêmico variou de 58 a 90 minutos (média 67,6 minutos), sendo que oito doadores estavam em hospitais da região metropolitana de São Paulo e dois em cidades distantes. Todos os enxertos, após completadas as anastomoses, retomaram o fluxo e o débito, mantendo bons parâmetros, com baixa dosagem de inotrópico e mantiveram estas condições no pós-operatório imediato. Não ocorreram óbitos e todos os pacientes obtiveram alta hospitalar. A evolução tardia variou de 20 dias a 10 meses, tendo ocorrido um óbito ao 4º mês pós-transplante, por sepse.

CONCLUSÕES:

Esta metodologia, além de reduzir o tempo isquêmico, permite ao órgão doado recuperar e manter seus batimentos sem pré nem pós-carga durante o implante, o que enseja proporcionar recuperação fisiológica, ultraestrutural, imunológica, inflamatória e mecânica do enxerto, com resultados consistentes precoces e tardios.
ABSTRACT
BACKGROUND AND

OBJECTIVE:

We attempt to reduce the ischemic time during implantation of the donor heart in the bicaval bipulmonary orthotopic position using normothermic beating heart and thus, facilitate the transplanted heart adaptation to the recipient. This study presents a small experience about a new strategy of myocardial protection during heart transplant.

METHODS:

In cardiopulmonary bypass, the aorta anastomosis was done first, allowing the coronary arteries to receive blood flow and the recovering of the beats. The rest of the anastomosis is performed on a beating heart in sinus rhythm. The pulmonary anastomosis is the last to be done. This methodology was applied in 10

subjects:

eight males, age 16-69 (mean 32.7 years), SPAo 90-100 mmHg (mean 96 mmHg), SPAP 25-65 mmHg (mean 46.1 mmHg), PVR 0.9 to 5.0 Wood (mean 3.17 Wood), GTP 4-13 mmHg (mean 7.9 mmHg), and eight male donors, age 15-48 years (mean 27.7 years), weight 65-114 kg (mean 83.1 kg). Causes of brain coma encephalic trauma in five hemorrhagic stroke in four, and brain tumor in one.

RESULTS:

The ischemic time ranged from 58-90 minutes (mean 67.6 minutes) and 8 donors were in hospitals of Sao Paulo and two in distant cities. All grafts assumed the cardiac output requiring low-dose inotropic therapy and maintained these conditions in the postoperative period. There were no deaths and all were discharged. The late evolution goes from 20 days to 10 months with one death occurred after 4 months due to sepsis.

CONCLUSION:

This method, besides reducing the ischemic time of the procedure, allows the donated organ to regain and maintain their beats without pre or after load during implantation entailing the physiological recovery of the graft.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Reperfusão Miocárdica / Transplante de Coração / Isquemia Miocárdica / Recuperação de Função Fisiológica / Coleta de Tecidos e Órgãos Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: IDPC/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Reperfusão Miocárdica / Transplante de Coração / Isquemia Miocárdica / Recuperação de Função Fisiológica / Coleta de Tecidos e Órgãos Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: IDPC/BR