Your browser doesn't support javascript.
loading
Diagnóstico microscópico de neumonía por Pneumocystis jirovecii en muestras de lavado broncoalveolar y lavado orofaríngeo de pacientes inmunocomprometidos con neumoníA / Microscopic diagnosis of Pneumocystis jirovecii pneumonia in bronchoalveolar lavage and oropharyngeal wash samples of immunocompromised patients with pneumonia
Rodiño, Jenniffer; Rincón, Nataly; Aguilar, Yudy Alexandra; Rueda, Zulma Vanessa; Herrera, Mariana; Vélez, Lázaro Agustín.
  • Rodiño, Jenniffer; Universidad de Antioquia. Facultad de Medicina. Grupo Investigador de Problemas en Enfermedades Infecciosas. Medellín. CO
  • Rincón, Nataly; Universidad de Antioquia. Escuela de Microbiología. Medellín. CO
  • Aguilar, Yudy Alexandra; Universidad de Antioquia. Corporación de Ciencias Básicas Médicas. Medellín. CO
  • Rueda, Zulma Vanessa; Universidad de Antioquia. Corporación de Ciencias Básicas Médicas. Medellín. CO
  • Herrera, Mariana; Universidad de Antioquia. Facultad Nacional de Salud Pública. Medellín. CO
  • Vélez, Lázaro Agustín; Universidad de Antioquia. Facultad de Medicina. Sección de Enfermedades Infecciosas. Medellín. CO
Biomédica (Bogotá) ; 31(2): 222-231, jun. 2011. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-617522
RESUMEN
Introducción. El diagnóstico de neumonía por Pneumocystis jirovecii se fundamenta en la visualización microscópica del hongo en secreciones respiratorias. Técnicas moleculares recientes también lo han detectado en muestras de orofaringe, pero su utilidad diagnóstica es discutible. En Colombia, hay poca información al respecto. Objetivo. Comparar el rendimiento de dos coloraciones, azul de toluidina O e inmunofluorescencia directa, en muestras de lavado broncoalveolar y lavado orofaríngeo en pacientes inmunocomprometidos con neumonía. Materiales y métodos. Se llevó a cabo un estudio transversal de evaluación de pruebas diagnósticas en 166 pacientes inmunocomprometidos con sospecha de neumonía por P. jirovecii. Por protocolo, las muestras de lavado broncoalveolar y orofaríngeo se citocentrifugaron y se colorearon con azul de toluidina e inmunofluorescencia. Se determinó la proporción de resultados positivos con ambas tinciones en cada una de las muestras, y la concordancia entre ellas. Resultados. Se detectaron 24 casos de neumonía por P. jirovecii en las muestras de lavado broncoalveolar (14,5 %), 21 de los cuales fueron positivos por ambas pruebas, mientras que tres casos se detectaron sólo por inmunofluorescencia. Ninguna de las 166 muestras de lavado orofaríngeo fue positiva por cualquiera de estas técnicas. Al comparar las proporciones de resultados positivos, no se encontraron desacuerdos significativos (p=0,63). La concordancia (coeficiente kappa) entre ellas fue de 0,92 (IC95%: 0,84-1). Conclusiones. Ambas coloraciones son útiles para diagnosticar neumonía por P. jirovecii en muestras de lavado broncoalveolar. Sin embargo, el azul de toluidina no detecta, aproximadamente, el 12 % de los casos positivos por inmunofluorescencia. Las muestras de lavado orofaríngeo no son apropiadas para detectar microscópicamente P. jirovecii.
ABSTRACT
Introduction. The diagnosis of Pneumocystis jirovecii pneumonia is based on observation of the microorganism using several staining techniques in respiratory samples, especially bronchoalveolar lavage and induced sputum. Recently, the fungus also has been detected in oropharyngeal wash samples, but only using molecular tests. Objective. The diagnostic yield of two microscopic stains, toluidine blue O and direct fluorescent antibody, was compared in bronchoalveolar lavage and oropharyngeal wash samples for the detection of P. jirovecii in immunocompromised patients with pneumonia. Materials and methods. Cross-sectional evaluation diagnostic tests were used in 166 immunossupressed patients with suspected P. jirovecii. By protocol, bronchoscopic bronchoalveolar lavage and oropharyngeal wash samples were prepared by cytocentrifugation, and slides were stained with toluidine blue and fluorescent antibody. The proportion of positive results from each stain and concordance between them were determined. Results. Twenty-four cases (14.5%) of P. jirovecii were detected in bronchoalveolar lavage samples. Of them, 21 were positive by both toluidine blue and fluorescent antibody stains, whereas 3 cases were detected by fluorescent antibody alone. None of the 166 oropharyngeal wash samples were positive by either of these techniques. No significant differences were found between proportions from positive results (p=0.63). Concordance (kappa coefficient) between both stains was 0.92 (95% CI: 0.84-1.00). Conclusions. Both techniques were useful to diagnose P. jirovecii in bronchoalveolar lavage samples. However, toluidine blue stain did not detect 12% of fluorescent antibody positive cases. Oropharyngeal wash samples do not provide sufficient material for the microscopic identification of this fungus.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Pneumonia por Pneumocystis / Cloreto de Tolônio / Técnica Direta de Fluorescência para Anticorpo / Lavagem Broncoalveolar Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica / Estudo observacional / Estudo de prevalência / Estudo prognóstico Idioma: Espanhol Revista: Biomédica (Bogotá) Assunto da revista: Medicina Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad de Antioquia/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Pneumonia por Pneumocystis / Cloreto de Tolônio / Técnica Direta de Fluorescência para Anticorpo / Lavagem Broncoalveolar Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica / Estudo observacional / Estudo de prevalência / Estudo prognóstico Idioma: Espanhol Revista: Biomédica (Bogotá) Assunto da revista: Medicina Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad de Antioquia/CO