Your browser doesn't support javascript.
loading
Oximetría de pulso como método de rastreo para macroangiopatía en diabéticos tipo 2: estudio prospectivo realizado en el hospital Luis Vernaza, de abril a septiembre de 2005 / Pulse oxymetry as a research method for diabetes 2 macroangiopathy: prospective study carried out in Luis Vernaza hospital, from abril to september/ 2005
Ortiz García, Jorge.
  • Ortiz García, Jorge; Universidad Católica de Santiago de Guayaquil. Facultad de Ciencias Médicas. Guayaquil. EC
Medicina (Guayaquil) ; 12(2): 137-145, jun. 2007.
Artigo em Espanhol | LILACS | ID: lil-617658
RESUMEN

Introducción:

Con esta investigación queremos conseguir un método de rastreo alternativo para el estudio de la vasculopatía periférica que sea útil, exacto, sencillo de aplicar, no invasivo y que brinde veracidad en sus resultados.

Métodos:

Estudio prospectivo en el que se enrolaron 30 pacientes a los que se realizó la historia clínica, el ABI (Ankle-Brachial Index) y la medición de la saturación de oxígeno en el dedo índice y en el primer dedo del pie. El ABI fue considerado anormal con un valor menor de 0.9 y la saturación de oxígeno del primer dedo del pie fue considerada anormal, si la diferencia era mayor del 2 en comparación con el dedo índice y con el pie elevado 12 pulgadas. Posteriormente comparamos dichos resultados.

Resultados:

Encontramos una correlación entre ABI y Oximetría de pulso de – 0.39; igualmente detectamos la siguiente relación a mayor edad y tiempo de diabetes, existieron valores mayores de desaturación de O2 en miembros inferiores, acompañados de valores menores de ABI, existiendo una correlación entre ellos de 88 según la tendencia que exhibieron los resultados.

Conclusiones:

La oximetría de pulso de miembros inferiores tanto en decúbito dorsal como elevada 12 pulgadas es tan exacta y segura como el ABI (Ankle-Brachial Index) en el rastreo de enfermedad arterial periférica en diabéticos tipo 2; y, la combinación de los dos, incrementa la sensibilidad.
ABSTRACT

Introduction:

With this research we want to achieve an alternative useful, precise, simple to administer, non-invasive tracing method for the study of peripheral vasculopathy. That method should also give truthful results.

Methods:

Prospective study for which 30 patients were signed on and all of them had case history, Ankle-Brachial Index (ABI) and measurement of oxygen saturation in the index finger and in the first toe. ABI was taken as abnormal if it is lower than 0.9 and oxygen saturation of the first toe was taken as abnormal if difference was higher than 2 compared with that of the index finger, with the foot raised 12 inches. Later those results were compared.

Results:

A correlation of -0.39 was found between ABI and pulse oxymetry. It was also detected this relation the older the patient and the longer he (her) has had diabetes, the higher his (her) O2 desaturation in lower limbs, with lower ABI. Correlation 88 according to the trend showed by the results.

Conclusions:

Lower limbs pulse oxymetry both face up and 12 inches up is so precise and definite as it is ABI (Ankle-Brachial Index) in the searching of a peripheral arterial disease in type 2 diabetics; and if both are used in combination, sensitivity increases.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Oximetria / Complicações do Diabetes / Diabetes Mellitus / Angiopatias Diabéticas Tipo de estudo: Estudo observacional / Estudo de rastreamento Limite: Adulto Idioma: Espanhol Revista: Medicina (Guayaquil) Assunto da revista: Ciˆncias da Sa£de / Medicina / Pesquisa / Sa£de P£blica Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Equador Instituição/País de afiliação: Universidad Católica de Santiago de Guayaquil/EC

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Oximetria / Complicações do Diabetes / Diabetes Mellitus / Angiopatias Diabéticas Tipo de estudo: Estudo observacional / Estudo de rastreamento Limite: Adulto Idioma: Espanhol Revista: Medicina (Guayaquil) Assunto da revista: Ciˆncias da Sa£de / Medicina / Pesquisa / Sa£de P£blica Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Equador Instituição/País de afiliação: Universidad Católica de Santiago de Guayaquil/EC