Your browser doesn't support javascript.
loading
Volume mediano efetivo de cristaloides na prevenção de hipotensão arterial em pacientes submetidas à cesariana com raquianestesia / The median effective volume of crystalloid in preventing hypotension in patients undergoing cesarean delivery with spinal anesthesia / Volumen mediano efectivo de cristaloides en la prevención de hipotensión arterial en pacientes sometidas a la cesárea con raquianestesia
ShiQin, Xu; HaiBo, Wu; QingSong, Zhao; XiaoFeng, Shen; XiRong, Guo; FuZhou, Wang.
  • ShiQin, Xu; Nanjing Medical University. CN
  • HaiBo, Wu; Nanjing Medical University. Nanjing Maternity and Child Health Care Hospital. CN
  • QingSong, Zhao; Nanjing Medical University. CN
  • XiaoFeng, Shen; Nanjing Medical University. CN
  • XiRong, Guo; Nanjing Medical University. CN
  • FuZhou, Wang; Nanjing Medical University. CN
Rev. bras. anestesiol ; 62(3): 318-324, maio-jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-626508
RESUMO
JUSTIFICATIVA E

OBJETIVOS:

A hipotensão materna associada à raquianestesia no parto cesáreo é a complicação mais frequente e problemática, com sérios riscos para a mãe e comprometimento do bem-estar neonatal. Nesse contexto, o volume efetivo de cristaloides por via intravenosa como uma estratégia de prevensão ainda não foi estimado.

MÉTODOS:

Oitenta e cinco parturientes com estado físico ASA I/II submetidas à cesariana seletiva foram selecionadas e 67 mulheres elegíveis foram designadas para receber uma pré-carga de cristaloides com 2 mL de bupivacaína hiperbárica a 0,5% (10 mg) mais 50 µg de morfina. O volume de cristaloides foi determinado por um método sequencial up-and-down. Os cristaloides foram infundidos a uma taxa de 100 a 150 mL.min-1 antes da anestesia espinal. O volume inicial de cristaloides foi de 5 mL.kg-1. Os dados do efeito do volume foram ajustados para o modelo sigmoidal de máxima eficácia e a mediana do volume efetivo (VE50) e seu intervalo de confiança (IC) de 95% foram calculados usando a estimativa de máxima verossimilhança e a regressão logística de Firth corrigida.

RESULTADOS:

Sessenta e sete parturientes completaram o estudo e foram analisadas. Vinte e oito pacientes (41,8%) desenvolveram hipotensão, com queda da pressão arterial sistólica (PAS) superior a 20% do valor basal. O VE50 de cristaloides foi de 12,6 mL.kg-1 (IC 95%, 11,6 a 14,8 mL.kg-1). Com a correção de Firth, a probabilidade conjunta do volume efetivo de cristaloides a 13 mL.kg-1 foi de 50,2% (IC 95%, 30,0% a 83,1%).

CONCLUSÕES:

O VE50 estimado da pré-carga de cristaloides necessário para prevenir a hipotensão induzida por anestesia espinhal em parto cesáreo é de 13 mL.kg-1 (valor aproximado). Porém, a profilaxia ou terapia com vasoconstritores também deve ser preparada e administrada no momento oportuno.
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Spinal anesthesia-associated maternal hypotension in Cesarean delivery is the most frequent and troublesome complication, posing serious risks to mothers and compromising neonatal well-being. The effective volume of intravenous crystalloid as the preventive strategy in this context has not been estimated.

METHODS:

Eighty-five parturients with ASA physical status I/II undergoing elective Cesarean delivery were screened and 67 eligible women were assigned to receive pre-spinal crystalloid loading. Hyperbaric 0.5% bupivacaine 2 mL (10 mg) plus morphine 50 µg was given to all patients. The volume of crystalloid was determined by an up-and-down sequential method. The crystalloid was infused at a rate of 100-150 mL.min-1 prior to the spinal anesthetic injection. The initial volume of crystalloid was 5 mL.kg-1. Volume-effect data were fitted to a sigmoidal maximum efficacy model and the median effective volume (EV50) and corresponding 95% confidence interval (95% CI) were estimated using maximum likelihood estimation and logistic regression with Firth's correction.

RESULTS:

A total of 67 subjects completed the study and were analyzed. Twenty-eight (41.8%) patients developed hypotension with their systolic blood pressure (SBP) decreasing > 20% of baseline. The EV50 of crystalloid were 12.6 mL.kg-1 (95% CI, 11.6 to 14.8 mL.kg-1). With Firth's correction, the pooled probability of an effective preventive volume of crystalloid at 13 mL.kg-1 was 50.2% (95% CI, 30% to 83.1%).

CONCLUSIONS:

The estimated EV50 of the preloaded crystalloid required to prevent spinal anesthesia-induced hypotension in a Cesarean section is, approximately, 13 mL.kg-1. However, prophylactic or therapeutic vasoconstrictors should also be prepared and administered at an appropriate time.
RESUMEN
JUSTIFICATIVA Y

OBJETIVOS:

La hipotensión materna asociada a la raquianestesia en el parto por cesárea es la complicación más común y problemática, acarreando serios riesgos para la madre y para el compromiso del bienestar neonatal. En ese contexto, el volumen efectivo de cristaloides por vía intravenosa como una estrategia de prevención todavía no ha sido estimado.

MÉTODOS:

Fueron elegidas ochenta y cinco parturientes con estado físico ASA I/II sometidas a la cesárea selectiva, y 67 mujeres elegibles fueron designadas para recibir una precarga de cristaloides con 2 mL de bupivacaína hiperbárica al 0,5% (10 mg) más 50 µg de morfina. El volumen de cristaloides quedó determinado por un método secuencial up-and-down. Los cristaloides fueron administrados a una tasa de 100 a 150 mL.min-1 antes de la anestesia espinal. El volumen inicial de cristaloides fue de 5 mL.kg-1. Los datos del efecto del volumen se ajustaron para el modelo sigmoidal de máxima eficacia y la mediana del volumen efectivo (VE50). El intervalo de confianza (IC) de 95% fue calculado usando la estimación de máxima verosimilitud y la regresión logística de Firth para la corrección.

RESULTADOS:

Sesenta y siete parturientes completaron el estudio y fueron analizadas. Veinte y ocho pacientes (41,8%) desarrollaron hipotensión, con una caída de presión arterial sistólica (PAS) superior al 20% del valor basal. El VE50 de cristaloides fue de 12,6 mL.kg-1 (IC 95%, 11,6 a 14,8 mL.kg-1). Con la corrección de Firth, la probabilidad conjunta del volumen efectivo de cristaloides a 13 mL.kg-1 fue de 50,2% (IC 95%, 30,0% a 83,1%).

CONCLUSIONES:

El VE50 estimado de la precarga de cristaloides necesario para prevenir la hipotensión inducida por anestesia espinal en el parto por cesárea es de 13 mL.kg-1 (valor aproximado). Sin embargo, la profilaxis o terapia con vasoconstrictores también debe ser preparada y administrada en el momento oportuno.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Cesárea / Hipotensão / Raquianestesia Tipo de estudo: Estudo prognóstico Limite: Feminino / Humanos / Gravidez Idioma: Português Revista: Rev. bras. anestesiol Assunto da revista: Anestesiologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: China Instituição/País de afiliação: Nanjing Medical University/CN

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Cesárea / Hipotensão / Raquianestesia Tipo de estudo: Estudo prognóstico Limite: Feminino / Humanos / Gravidez Idioma: Português Revista: Rev. bras. anestesiol Assunto da revista: Anestesiologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: China Instituição/País de afiliação: Nanjing Medical University/CN