Your browser doesn't support javascript.
loading
Validación del método ultravioleta para determinar fósforo en suero / Validation of ultraviolet method to determine serum phosphorus level
García Borges, Lisandra; Pérez Prieto, Teresa María; Valdés Diez, Lilliam.
  • García Borges, Lisandra; Empresa de Producción de Biológicos Carlos J. Finlay. La Habana. CU
  • Pérez Prieto, Teresa María; Empresa de Producción de Biológicos Carlos J. Finlay. La Habana. CU
  • Valdés Diez, Lilliam; Empresa de Producción de Biológicos Carlos J. Finlay. La Habana. CU
Rev. cuba. farm ; 43(4): 45-52, sep.-dic. 2009.
Artigo em Espanhol | LILACS | ID: lil-628428
RESUMEN
Se presentó la validación de un método espectrofotométrico aplicable en los laboratorios clínicos para la determinación analítica de fosfatos en suero, con el uso del juego de reactivos fósforo-UV de producción nacional de la Empresa de Producción de Biológicos "Carlos J. Finlay" (La Habana, Cuba). El método de análisis se fundamentó en la reacción del fósforo con amonio molibdato a pH ácido para formar un complejo medible a 340 nm. Se evaluaron la especificidad y precisión teniendo en cuenta la robustez del método, linealidad, exactitud y sensibilidad del método. El método analítico resultó ser lineal hasta 4,8 mmol/L, preciso (CV < 3 %) y exacto (% recuperación 98 a 102 %; r ³ 0,999) en el intervalo de concentraciones de interés clínico, donde no se registraron interferencias por la matriz. Los valores para el límite de detección fueron de 0,037 mmol/L y de cuantificación de 0,13 mmol/L, ambos satisfactorios para el uso al que se destina el producto.
ABSTRACT
Validation of a spectrophotometry method applicable in clinic labs was proposed to analytical assessment of serum phosphates using a kit UV-phosphorus of domestic production from "Carlos J. Finlay" Biologics Production Enterprise (Havana, Cuba). Analysis method was based on phosphorus reaction to ammonium molybdenum to acid pH to creating a measurable complex to 340 nm. Specificity and precision were measured considering the method strength, linearity, accuracy and sensitivity. Analytical method was linear up to 4,8 mmol/L, precise (CV < 3 %) and exact (% recovery 98 to 102 %; r ³ 0.999) during clinical interest concentration interval where there were not interferences by matrix. Detection limit values were of 0.037 mmol/L and of quantification of 0.13 mmol/L both were satisfactory for product use.

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. cuba. farm Assunto da revista: Farmácia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Empresa de Producción de Biológicos Carlos J. Finlay/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Rev. cuba. farm Assunto da revista: Farmácia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Empresa de Producción de Biológicos Carlos J. Finlay/CU