Microfiltración coronaria in vitro de streptococcus mutans, a través de tres cementos provisionales en dientes tratados endodóncicamente / Microfiltration coronary mutans streptococci in vitro, through three cements endodontically treated teeth interim
Acta odontol. venez
;
46(3): 301-310, dic. 2008. graf, tab
Artigo
em Espanhol
| LILACS
| ID: lil-630081
RESUMEN
La microfiltración coronaria se considera una causa del fracaso de los tratamientos de conductos radiculares. El propósito de la presente investigación in vitro, fue evaluar la capacidad para prevenir la microfiltración coronaria de Streptococcus mutans de IRM®, Cavit®, ionómero de vidrio GC Fuji I® en dientes tratados endodóncicamente, durante un período de 90 días. Se realizó un diseño experimental con 40 dientes humanos extraídos, cortados coronariamente a una longitud radicular de 14mm, cuyos conductos fueron preparados, obturados con gutapercha y sellador con técnica de condensación lateral, previa remoción de la capa de desecho. Las cavidades de acceso fueron estandarizadas, a una profundidad de 4mm. La muestra se dividió en: Grupo Experimental: 30 dientes (10 por material de obturación provisional) y Grupo Control: 10 dientes (5 control positivo, 5 control negativo). Se utilizó un sistema de filtración con doble cámara. La cámara inferior se evaluó diariamente para observar la turbidez del caldo de cultivo y establecer la presencia y el día de la filtración. Las muestras del control positivo filtraron los primeros 7 días, el control negativo no mostró filtración. El grupo "IRM" mostró un 100 por ciento de muestras filtradas, el grupo "CAVIT" un 60 por ciento y el grupo "FI" un 40 por ciento. El promedio de días para la filtración de los grupos "IRM", "CAVIT" y "FI" fue 25,4 , 28,67 y 56,75 respectivamente. Se concluyó que el material de obturación provisional que mostró mayor capacidad para prevenir la microfiltración coronaria fue el ionómero de vidrio
ABSTRACT
The coronal microleakage is cause of endodontic failure. The purpose of this study in vitro was to evaluate the ability of IRM®, Cavit® and glass ionomers GC Fuji I® to prevent the coronal leakage of S. mutans in endodontically treated teeth to 90 days. Forty intact extracted human teeth were coronally shortened to a uniform length of 14 mm. The root canal were prepared and obtured with sealer and gutapercha with lateral condensation. The dentinal smear layer was removed before obturation. Standardized access cavities to 4mm depth. The teeth were divided in two groups: Experimental group (30 teeth) and Control group (10 teeth). The teeth were placed into a coronal leakage apparatus that contained an upper and lower chamber, daily observations were made for bacterial growth and for determine the length of time for the bacteria to penetrate complete of canal root. All positive control teeth showed bacterial penetration in the first 7 days, while the negative control teeth no showed contaminatied thoughout the test period. The groups "IRM" showed 100 percent leakage, "CAVIT" 60 percent and "FI"40 percent . The mean measure days for group "IRM", "CAVIT" and "FI" were 25,4 , 28,67 and 56,75 respectivement
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Streptococcus mutans
/
Micropeneiramento
/
Coroas
/
Cemento Dentário
/
Endodontia
Tipo de estudo:
Estudos de avaliação
Limite:
Humanos
Idioma:
Espanhol
Revista:
Acta odontol. venez
Assunto da revista:
Medicina Bucal
/
Odontologia
/
Sa£de Bucal
Ano de publicação:
2008
Tipo de documento:
Artigo
País de afiliação:
Venezuela
Instituição/País de afiliação:
Universidad Central de Venezuela/VE
Similares
MEDLINE
...
LILACS
LIS