Precisión de la tomografía de 64 cortes en el diagnóstico de reestenosis de stent coronario / Accuracy of the 64 multislice computed tomography in the diagnosis of coronary stent restenosis
Arch. cardiol. Méx
;
81(1): 3-10, ene.-mar. 2011. ilus
Artigo
em Espanhol
| LILACS
| ID: lil-631991
RESUMEN
Objetivo:
Determinar la precisión de la coronariografía por tomografía de 64 cortes para la detección de la reestenosis de los stents.Método:
Se examinaron 52 pacientes portadores de 76 stents coronarios con sospecha de reestenosis. Inicialmente se les realizó coronariografía mediante tomógrafo de 64 cortes y posteriormente coronariografía invasiva como patrón de referencia. Se calcularon los índices de eficiencia diagnóstica.Resultados:
En los stents valorables de 3 mm o más de diámetro, la sensibilidad, especificidad, valor predictivo positivo y negativo de la tomografía fueron de 95, 98, 95 y 98% respectivamente, con razón de verosimilitud positiva de 42 (IC95%, 6 a 290) y negativa de 0.05 (IC95%, 0.01 a 0.35), validez de 97% y Kappa de 0.93 (IC95%, 0.83 a 1), (p ≤ 0.00001). En los stents valorables menores que 3 mm, disminuyeron apreciablemente los índices de eficiencia diagnóstica y de Kappa, perdiendo la significancia estadística (p > 0.05).Conclusión:
La coronariografía por tomografía de 64 cortes es una técnica clínica no invasiva precisa, en la detección de la reestenosis de los stents, sobre todo en los stents de 3 mm o más, y segura, ya que permite identificar a los pacientes que necesitan o no la realización de una coronariografía invasiva de control.ABSTRACT
Objective:
To determine the accuracy of coronary angiography through 64-slice computed tomography in detecting in-stent restenosis.Method:
Fifty-two patients with 76 coronary stents and suspicion of restenosis were examined. Initially, they underwent coronary angiography through 64-slice computed tomography, and subsequently invasive coronary angiography as gold standard. Diagnostic efficiency indexes were calculated.Results:
In the stents of 3 mm or more of diameter, tomography sensitivity, specificity, positive and negative predictive value were 95, 98, 95 and 98% respectively, with positive likelihood ratio of 42 (CI95%, 6 to 290) and negative of 0.05 (CI95%, .01 to .35), validity of 97% and Kappa of 0.93 (CI95%, .83 to 1), (p ≤ 0.00001). In the stents smaller than 3 mm, the indexes of diagnostic efficiency and Kappa considerably decreased, loosing the statistical significance (p >0.05).Conclusions:
Coronary angiography through 64-slice computed tomography is an accurate, non-invasive clinical technique for the detection of in-stent restenosis, especially with stents of 3 mm or more of diameter, and reliable allows identification of patients who need to undergo or not control invasive coronary angiography.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Stents
/
Reestenose Coronária
/
Tomografia Computadorizada Multidetectores
Tipo de estudo:
Estudo diagnóstico
/
Estudo observacional
/
Estudo de prevalência
/
Estudo prognóstico
/
Fatores de risco
Limite:
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Arch. cardiol. Méx
Assunto da revista:
Cardiologia
Ano de publicação:
2011
Tipo de documento:
Artigo
País de afiliação:
Cuba
Instituição/País de afiliação:
Instituto Nacional de Cardiología y Cirugía Cardiovascular/CU
Similares
MEDLINE
...
LILACS
LIS