Your browser doesn't support javascript.
loading
Prueba de adenosina en el síncope de origen desconocido: ¿queda algún espacio para su indicación? / Is There Any Room for Adenosine Test in Syncope of Unknown Origin?
Albina, Gastón; Scazzuso, Fernando; Sammartino, Victoria; Rivera, Santiago; Laiño, Rubén; Giniger, Alberto.
  • Albina, Gastón; - Instituto Cardiovascular de Buenos Aires. Servicio de Electrofisiología y Arritmias. Buenos Aires. AR
  • Scazzuso, Fernando; - Instituto Cardiovascular de Buenos Aires. Servicio de Electrofisiología y Arritmias. Buenos Aires. AR
  • Sammartino, Victoria; - Instituto Cardiovascular de Buenos Aires. Servicio de Electrofisiología y Arritmias. Buenos Aires. AR
  • Rivera, Santiago; - Instituto Cardiovascular de Buenos Aires. Servicio de Electrofisiología y Arritmias. Buenos Aires. AR
  • Laiño, Rubén; - Instituto Cardiovascular de Buenos Aires. Servicio de Electrofisiología y Arritmias. Buenos Aires. AR
  • Giniger, Alberto; - Instituto Cardiovascular de Buenos Aires. Servicio de Electrofisiología y Arritmias. Buenos Aires. AR
Rev. argent. cardiol ; 79(1): 9-13, ene.-feb. 2011. graf, tab
Artigo em Espanhol | LILACS | ID: lil-634232
RESUMEN
Introducción Algunos pacientes con síncope inexplicado desarrollan distintos grados de bloqueo AV paroxístico con la infusión en bolo de 18 mg de adenosina. Este hallazgo tuvo un valor predictivo positivo bajo en ensayos recientes, aunque su utilización no estuvo normatizada. Objetivo Presentar la experiencia en nuestra institución en el seguimiento de pacientes con un primer episodio de síncope de origen desconocido (SOD) maligno, a quienes se les realizó sistemáticamente una prueba de adenosina. Material y métodos Se incluyeron en forma prospectiva y consecutiva pacientes que presentaban síncope inexplicado con traumatismo grave, sin antecedentes sincopales previos, sin sospecha de etiología vagal, sin cardiopatía orgánica, con estudios neurológicos y cardiológicos normales (incluido tilt test sensibilizado), a los que se les realizó una prueba de adenosina. La prueba se efectuó al final del estudio electrofisiológico. Se infundieron en bolo 18 mg de adenosina por la vena femoral bajo monitorización electrocardiográfica continua; se definió prueba positiva al desarrollo de bloqueo AV completo con pausa mayor de 6 segundos. Resultados Entre 1999 y 2009 se les realizó una prueba de adenosina a 29 pacientes (edad promedio 63 ± 12 años, 17 mujeres). La prueba fue positiva en 17, con una pausa promedio de 10.185± 3.430 mseg. La edad promedio de este grupo fue de 64 ± 13 años, 13 eran mujeres. En los 12 pacientes restantes (59 ± 11 años), la prueba fue negativa, con una pausa promedio de 2.570 ± 1.067 mseg. Todos recibieron recomendaciones higiénico-dietéticas para la prevención del síncope neuromediado y en 9 pacientes con prueba de adenosina positiva se implantó un marcapasos definitivo. El seguimiento fue de 51 ± 37 meses. Sólo 2 pacientes tuvieron recurrencia del síncope, ambos con prueba de adenosina positiva y sin implante de marcapasos. Conclusiones Los pacientes con síncope de origen desconocido y riesgo inicial alto representan en el seguimiento una población de riesgo clínico bajo, con una tasa de recurrencia muy baja, independientemente de la estrategia terapéutica implementada.
ABSTRACT
Background Few patients with unexplained syncope develop different degrees of paroxysmal AV block after the infusion of 18 mg of adenosine. Recent trials have reported that the positive predictive value of this finding is low; yet the use of the test has not been standardized. Objective To present our experience with follow-up of patients with a first episode of malignant syncope of unknown origin (SUO) who underwent adenosine test. Material and Methods We included patients with unexplained syncope and severe trauma in a consecutive and prospective fashion. None of the patients had a previous history of syncope, and vasovagal syncope was not suspected. Structural heart diseases were ruled out. Neurological and cardiovascular tests were normal (including sensitized TT). All the participants underwent adenosine test after the electrophisiologic study. A bolus of 18 mg of adenosine was administered via the femoral vein under continuous electrocardiographic monitoring. A positive test was defined by the development of complete AV block with pauses longer than 6 seconds. Results Between 1999 and 2009, adenosine test was performed in 29 patients (mean age 63±12 years, 17 were women). The test was positive in 7 patients, and the mean duration of pauses was 10.185±3.430 ms. Mean age in this group was 64±13 years, 13 were women. The test was negative in the remaining 12 patients (59±11 years, mean pauses 2.570±1.067 ms. All patients were received information about hygienic and dietetic measures to prevent neurocardiogenic syncope, and a definite pacemaker was implanted in 9 patients with positive adenosine test. Follow-up was 51±37 months. Syncope recurrence occurred in only 2 patients with positive adenosine test who did not undergo pacemaker implantation. Conclusions Patients with syncope of unknown origin and initial high risk represent a population of low clinical risk during followup, with low recurrence rate regardless of the therapeutic strategy used.

Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Guia de Prática Clínica / Estudo prognóstico Idioma: Espanhol Revista: Rev. argent. cardiol Assunto da revista: Cardiologia / Doen‡as Cardiovasculares Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: - Instituto Cardiovascular de Buenos Aires/AR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Guia de Prática Clínica / Estudo prognóstico Idioma: Espanhol Revista: Rev. argent. cardiol Assunto da revista: Cardiologia / Doen‡as Cardiovasculares Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: - Instituto Cardiovascular de Buenos Aires/AR