Your browser doesn't support javascript.
loading
Concordancia de las técnicas subjetivas que miden la amplitud de acomodación / Concordance between subjective techniques that measure amplitude of accommodation
León Álvarez, Alejandro; Estrada, Jorge Mario; Lizcano, Ketty Cruz; López Guzmán, Jennifer.
  • León Álvarez, Alejandro; Fundación del Area Andina. Pereira. CO
  • Estrada, Jorge Mario; Fundación del Area Andina. Pereira. CO
  • Lizcano, Ketty Cruz; Fundación del Area Andina. Pereira. CO
  • López Guzmán, Jennifer; Fundación Area Andina. Pereira. CO
Cienc. tecnol. salud vis. ocul ; 8(2): 141-151, jul.- dic. 2010. tab, graf
Artigo em Espanhol | LILACS | ID: lil-653301
RESUMEN

Objetivo:

determinar la repetitividad inter observador y la concordancia entre las pruebas e s que miden la amplitud de acomodación (AA).

Metodología:

fueron evaluados setenta y nueve sujetos entre los 18 a 30 años, que presentaban un estado visual refractivo y acomodativo normales. Las pruebas clínicas realizadas fueron la técnica de Sheard (lente negativo de cerca) Jackson (lente negativo de lejos) y Donders modificada (alejamiento más un lente de -4.00D).

Resultados:

el Coeficiente de Correlación Intraclase (ICC) mostró que las pruebas de mostraban una alta repetitividad (>0,7); el Coeficiente de Correlación y Concordancia de Lin (ρc) reveló una pobre repetitividad y concordancia entre las pruebas (ρc≤0,9). Los límites de acuerdo para Donders, Sheard y Jackson (+/-1,22; +/-2,02, +/-3,44) revelan una menor variación de la AA entre los observadores para Donders y mayor para Jackson.

Conclusión:

la repetitividad inter observadora es mayor para la técnica de Donders modificada y la concordancia entre las pruebes pobre, por lo que no son intercambiables.
ABSTRACT
The purpose was determinate reliability test retest and concordance between clinical techniques that measure amplitude of accommodation.

Methods:

seventy nine students who had normal visual function, refractive and accommodative skills participated. The techniques were minus lens (near), minus lens (far) and push down modified (-4.00D lens).

Results:

Intraclass Correlation Coefficient (ICC) show that test retest was high three techniques (>0,7); Concordance correlation coefficient of Lin (ρc) showed that agreement was poor for all of them (ρc≤0,9). Limits of agreement (95%) were push down modified +/-1,22; minus lens near +/-2,02; minus lens far +/- 3,44.

Conclusion:

reliability test retest was higher for push down modified and concordance between the techniques was poor so, these are not interchangeable.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Acomodação Ocular Limite: Humanos Idioma: Espanhol Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: Informática Médica / Oftalmologia / Optometria / TECNOLOGIA Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Area Andina/CO / Fundación del Area Andina/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Acomodação Ocular Limite: Humanos Idioma: Espanhol Revista: Cienc. tecnol. salud vis. ocul Assunto da revista: Informática Médica / Oftalmologia / Optometria / TECNOLOGIA Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Fundación Area Andina/CO / Fundación del Area Andina/CO