Concordancia de las técnicas subjetivas que miden la amplitud de acomodación / Concordance between subjective techniques that measure amplitude of accommodation
Cienc. tecnol. salud vis. ocul
;
8(2): 141-151, jul.- dic. 2010. tab, graf
Artigo
em Espanhol
| LILACS
| ID: lil-653301
RESUMEN
Objetivo:
determinar la repetitividad inter observador y la concordancia entre las pruebas e s que miden la amplitud de acomodación (AA).Metodología:
fueron evaluados setenta y nueve sujetos entre los 18 a 30 años, que presentaban un estado visual refractivo y acomodativo normales. Las pruebas clínicas realizadas fueron la técnica de Sheard (lente negativo de cerca) Jackson (lente negativo de lejos) y Donders modificada (alejamiento más un lente de -4.00D).Resultados:
el Coeficiente de Correlación Intraclase (ICC) mostró que las pruebas de mostraban una alta repetitividad (>0,7); el Coeficiente de Correlación y Concordancia de Lin (ρc) reveló una pobre repetitividad y concordancia entre las pruebas (ρc≤0,9). Los límites de acuerdo para Donders, Sheard y Jackson (+/-1,22; +/-2,02, +/-3,44) revelan una menor variación de la AA entre los observadores para Donders y mayor para Jackson.Conclusión:
la repetitividad inter observadora es mayor para la técnica de Donders modificada y la concordancia entre las pruebes pobre, por lo que no son intercambiables.ABSTRACT
The purpose was determinate reliability test retest and concordance between clinical techniques that measure amplitude of accommodation. Methods:
seventy nine students who had normal visual function, refractive and accommodative skills participated. The techniques were minus lens (near), minus lens (far) and push down modified (-4.00D lens).Results:
Intraclass Correlation Coefficient (ICC) show that test retest was high three techniques (>0,7); Concordance correlation coefficient of Lin (ρc) showed that agreement was poor for all of them (ρc≤0,9). Limits of agreement (95%) were push down modified +/-1,22; minus lens near +/-2,02; minus lens far +/- 3,44.Conclusion:
reliability test retest was higher for push down modified and concordance between the techniques was poor so, these are not interchangeable.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Acomodação Ocular
Limite:
Humanos
Idioma:
Espanhol
Revista:
Cienc. tecnol. salud vis. ocul
Assunto da revista:
Informática Médica
/
Oftalmologia
/
Optometria
/
TECNOLOGIA
Ano de publicação:
2010
Tipo de documento:
Artigo
País de afiliação:
Colômbia
Instituição/País de afiliação:
Fundación Area Andina/CO
/
Fundación del Area Andina/CO
Similares
MEDLINE
...
LILACS
LIS