Your browser doesn't support javascript.
loading
A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment
Andrade, Pâmela Cândida Aires Ribas de; Luthi, Leonardo Flores; Stanley, Kyle; Cardoso, Antônio Carlos.
  • Andrade, Pâmela Cândida Aires Ribas de; Federal University of Santa Catarina. Department of Implant Dentistry. Florianópolis. BR
  • Luthi, Leonardo Flores; University of Campinas. Piracicaba School of Dentistry. Department of Dental Materials and Prosthodontics. Piracicaba. BR
  • Stanley, Kyle; Federal University of Santa Catarina. Department of Implant Dentistry. Florianópolis. BR
  • Cardoso, Antônio Carlos; Federal University of Santa Catarina. Department of Implant Dentistry. Florianópolis. BR
J. appl. oral sci ; 20(5): 517-521, Sept.-Oct. 2012. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-654914
ABSTRACT
OBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. CONCLUSION: Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Vibração / Técnica de Fundição Odontológica / Dente Suporte / Adaptação Marginal Dentária / Prótese Dentária Fixada por Implante / Modelos Dentários Tipo de estudo: Ensaio Clínico Controlado / Estudos de avaliação / Estudo prognóstico Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Santa Catarina/BR / University of Campinas/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Vibração / Técnica de Fundição Odontológica / Dente Suporte / Adaptação Marginal Dentária / Prótese Dentária Fixada por Implante / Modelos Dentários Tipo de estudo: Ensaio Clínico Controlado / Estudos de avaliação / Estudo prognóstico Idioma: Inglês Revista: J. appl. oral sci Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Santa Catarina/BR / University of Campinas/BR