Your browser doesn't support javascript.
loading
Reproducibilidad de las pruebas Arm Curly Chair Stand para evaluar resistencia muscular en población adulta mayor / Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people / Reprodutibilidade dos testes de Arm Curl e Chair Stand para avaliar resistência muscular em idosos
Boneth Collantes, Milena; Ariza García, Claudia Lucía; Angarita Fonseca, Adriana; Parra Patiño, Javier; Monsalve, Andrea; Gómez, Eliana.
  • Boneth Collantes, Milena; Universidad de Santander, UDES. Grupo CliniUDES. CO
  • Ariza García, Claudia Lucía; Universidad de Santander, UDES. Grupo CliniUDES. CO
  • Angarita Fonseca, Adriana; Universidad de Santander, UDES. Grupo CliniUDES. CO
  • Parra Patiño, Javier; Universidad Industrial de Santander. Escuela de Fisioterapia. CO
  • Monsalve, Andrea; Universidad de Santander, UDES. CO
  • Gómez, Eliana; Universidad de Santander, UDES. CO
Rev. cienc. salud (Bogotá) ; 10(2): 179-193, mayo-ago. 2012. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-663746
RESUMEN

Objetivo:

evaluar la reproducibilidad prueba-reprueba y el nivel de acuerdo entre mediciones de las pruebas 30 seg (30-s) Arm Curl y 30-s Chair Stand en una muestra de adultos mayores de Bucaramanga. Materiales y

métodos:

se realizó un estudio de evaluación de tecnologías diagnósticas. Ambas pruebas fueron administradas en dos oportunidades por el mismo evaluador a 111 adultos mayores de 59 años (70,4 ± 7,3), con un intervalo de 4 a 8 días. En el análisis se determinó la reproducibilidad prueba-reprueba mediante el coeficiente de correlación intraclase, CCI= 2,1 con sus respectivos intervalos de confianza de 95% (IC 95%). El nivel de acuerdo se estableció mediante el método de Bland y Altman.

Resultados:

la reproducibilidad prueba-reprueba para el 30-s Arm Curl test fue muy buena, con un CCI= 0,88 y para el 30-s Chair Stand test fue buena, con un CCI= 0,78. Así, el acuerdo fue muy bueno para las dos pruebas de resistencia muscular. Los IC 95% estuvieron entre -3,8 y 3,2 repeticiones para la prueba 30-s Chair Stand y entre -3,1 y 2,8 repeticiones para la prueba 30-s Arm Curl.

Conclusión:

las pruebas 30-s Arm Curl y 30-s Chair Stand tienen buena reproducibilidad y nivel de acuerdo para evaluar resistencia muscular en adultos mayores funcionalmente independientes.
ABSTRACT

Objective:

to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s) Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and

methods:

a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3), on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95%) respective. The agreement level was established by the Bland and Altman method.

Results:

the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test.

Conclusion:

the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.
RESUMO

Objetivo:

avaliar a reprodutibilidade teste-reteste e nível de concordância entre as medidas de testes 30 second (30-s) Arm Curl e 30-s Chair Stand em uma amostra de idosos de Bucaramanga.

Materiais e métodos:

se realizou um estudo de avaliação da tecnologia de diagnóstico. Ambos os testes foram administrados pelo mesmo avaliador a 111 adultos com mais de 59 anos de idade (70,4 ± 7,3), em duas ocasiões, com um intervalo de tempo entre as medidas de 4 a 8 dias. Na análise, se determinou a reprodutibilidade teste-reteste usando o Coeficiente de Correlação Intraclasse ICC= 2,1 com seus respectivos intervalos de confiança de 95% (IC 95%). O nível de concordância foi estabelecido pelo método de Bland e Altman.

Resultados:

a reprodutibilidade teste-reteste do 30-s Arm Curl teste era muito bom ICC= 0,88 e do 30-s Chair Stand teste foi boa ICC= 0,78. O acordo foi muito bom para ambos os testes de resistência muscular. Os IC 95% foram de -3,8 e 3,2 repetições para o 30-s Chair Stand teste e de -3,1 e 2,8 repetições para o 30-s Arm Curl teste.

Conclusão:

testes 30-s Arm Curl e 30-s Chair Stand possui boa reprodutibilidade e concordância para avaliar a resistência muscular em idosos funcionalmente independentes.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aptidão Física Tipo de estudo: Estudo diagnóstico / Estudos de avaliação / Avaliação de Tecnologias em Saúde Limite: Idoso / Humanos País/Região como assunto: América do Sul / Colômbia Idioma: Espanhol Revista: Rev. cienc. salud (Bogotá) Assunto da revista: Medicina / Sa£de P£blica / Terapias Complementares Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad Industrial de Santander/CO / Universidad de Santander, UDES/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aptidão Física Tipo de estudo: Estudo diagnóstico / Estudos de avaliação / Avaliação de Tecnologias em Saúde Limite: Idoso / Humanos País/Região como assunto: América do Sul / Colômbia Idioma: Espanhol Revista: Rev. cienc. salud (Bogotá) Assunto da revista: Medicina / Sa£de P£blica / Terapias Complementares Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad Industrial de Santander/CO / Universidad de Santander, UDES/CO