Your browser doesn't support javascript.
loading
Microbial contamination of single-and multiple-dose vials after opening in a pulmonary teaching hospital
Baniasadi, Shadi; Dorudinia, Atosa; Mobarhan, Mandana; Gamishan, Masoumeh Karimi; Fahimi, Fanak.
  • Baniasadi, Shadi; Shahid Beheshti University of Medical Sciences. National Research Institute of Tuberculosis and Lung Diseases. Virology Research Center. Tehran. IR
  • Dorudinia, Atosa; Shahid Beheshti University of Medical Sciences. National Research Institute of Tuberculosis and Lung Diseases. Virology Research Center. Tehran. IR
  • Mobarhan, Mandana; Shahid Beheshti University of Medical Sciences. National Research Institute of Tuberculosis and Lung Diseases. Virology Research Center. Tehran. IR
  • Gamishan, Masoumeh Karimi; Shahid Beheshti University of Medical Sciences. National Research Institute of Tuberculosis and Lung Diseases. Virology Research Center. Tehran. IR
  • Fahimi, Fanak; Shahid Beheshti University of Medical Sciences. National Research Institute of Tuberculosis and Lung Diseases. Virology Research Center. Tehran. IR
Braz. j. infect. dis ; 17(1): 69-73, Jan.-Feb. 2013. tab
Artigo em Inglês | LILACS | ID: lil-665777
ABSTRACT

OBJECTIVES:

Intravenous therapy is a complex procedure usually requiring the preparation of the medication in the clinical area before administration to the patient. Breaches in aseptic technique may result in microbial contaminations of vials which is a potential cause of different avoidable infections. We aimed to investigate the prevalence and pattern of microbial contamination of single- and multiple-dose vials in the largest pulmonary teaching hospital in Iran.

METHODS:

In a period of 2 months, opened single- and multiple-dose vials from different wards were sampled by a pharmacist. The name of the medication, ward, labeling of the vials, the date of opening, and storing temperature were recorded for each vial. Remained contents of each vial were cultured using appropriate bacterial and fungal growth media.

RESULTS:

Microbial contamination was identified in 11 of 205 (5.36%) of vials. The highest contamination rate was 14.28% for vials used in interventional bronchoscopy unit. The most frequent contaminated medication was insulin. Gram-positive bacteria (81.82%) were more significantly involved than gram-negative ones (9.09%) and fungi (9.09%), with the highest frequency for Staphylococcus epidermidis .

CONCLUSIONS:

Our data demonstrate that repeated use of vials especially if basic sterility measures are disobeyed can cause microbial contamination of administered products to the patients. Infection preventionists are responsible to train health care workers regarding aseptic techniques and apply guidelines for aseptic handling of intravenous solutions.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Seringas / Contaminação de Equipamentos / Catéteres / Fungos / Bactérias Gram-Negativas / Bactérias Gram-Positivas Tipo de estudo: Guia de Prática Clínica / Fatores de risco País/Região como assunto: Ásia Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Irã Instituição/País de afiliação: Shahid Beheshti University of Medical Sciences/IR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Seringas / Contaminação de Equipamentos / Catéteres / Fungos / Bactérias Gram-Negativas / Bactérias Gram-Positivas Tipo de estudo: Guia de Prática Clínica / Fatores de risco País/Região como assunto: Ásia Idioma: Inglês Revista: Braz. j. infect. dis Assunto da revista: Doenças Transmissíveis Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Irã Instituição/País de afiliação: Shahid Beheshti University of Medical Sciences/IR