Your browser doesn't support javascript.
loading
Efeito do ciclo de polimerização sobre a dureza de resinas acrílicas para base de prótese polimerizadas convencionalmente ou em micro-ondas / Effect of polymerization cycle on hardness of denture base acrylic resins polymerized by conventional water bath or microwave irradiation
Moreno, Bruno Rosolen; Furlan, William Silveira; Neppelenbroek, Karin Hermana; Campanha, Nara Hellen; Jorge, Janaina Habib; Urban, Vanessa Migliorini.
  • Moreno, Bruno Rosolen; s.af
  • Furlan, William Silveira; s.af
  • Neppelenbroek, Karin Hermana; Universidade de São Paulo. Faculdade de Odontologia. Bauru. BR
  • Campanha, Nara Hellen; s.af
  • Jorge, Janaina Habib; s.af
  • Urban, Vanessa Migliorini; s.af
Rev. ABO nac ; 19(1): 29-33, fev.-mar. 2011. tab
Artigo em Português | LILACS, BBO | ID: lil-667640
RESUMO

Introdução:

O tempo de polimerização reduz-se significativamente com a utilização do micro-ondas e esse método pode polimerizar com eficiência as resinas acrílicas para base de prótese. O objetivo deste estudo foi avaliar o efeito de ciclos de polimerização, em banho de água aquecida(B) e em micro-ondas (M), sobre a dureza de resinas acrílicas formuladas para serem processadas convencionalmente (Vipi Cril®-VC) ou por micro-ondas (Vipi Wave®-VW). Material e Métodos- Corpos de prova (n=8) foram confeccionados nas dimensões de 64x10x3,3 mm e armazenados em água destilada em estufa a 37ºC por 48h. Amostras de cada material termopolimerizável convencional(VC) ou para micro-ondas (VW) foram divididas aleatoriamente em dois grupos ciclos de polimerização recomendados pelo fabricante em banho de água aquecida (VCB e VWB) ou em micro-ondas (VCM e VWM). As mensurações de dureza (VHN) foram realizadas utilizando-se um microdurômetro Vickers com carga de 50g durante 10s. Os resultados foram submetidos à ANOVA2 fatores seguida pelo teste de Tukey (α=0,05). Resultados - Independentemente do ciclo utilizado,não houve diferença estatisticamente significante entre os materiais avaliados (P=0,38). Foram observados valores de dureza maiores (P=0,00003) quando os ciclos de polimerização das resinas acrílicas foram invertidos (VCM=48,2>VCB=32,9; VWB=50,5>VWM=24,1). Conclusões - As resinas acrílicas apresentaram valores de dureza sem diferença significativa quando polimerizadas de acordo com as instruções do fabricante. A polimerização da resina Vipi Cril em micro-ondas e da resina Vipi Wave em banho de água resultou em valores de dureza superiores.
ABSTRACT

Introduction:

The processing time is significantly reduced with using microwave and this method can efficiently polymerize denture base acrylic resins. The aim of this study was to evaluate the effect of water-bath (W) and microwave (M) polymerization cycles on hardness of water-bath (VipiCril®-VC) or microwave-polymerized acrylic resin (Vipi Wave®-VW). Material and Methods -Specimens (n=8) of the heat-polymerized denture base acrylic resins were made (64x10x3.3 mm)and stored in distilled water at 37ºC during 48h. After that, specimens of water-bath polymerized(VC) or microwave processed (VW) materials were randomly divided into two groups according to the polymerization cycles recommended by the manufacturer water-bath (VCW and VWW)or microwave irradiation (VCM and VWM). Hardness measurements (VHN) were made with ahardness tester operated under a 50-g load and a 10-second dwell time. Results were analyzed with 2-way ANOVA and Tukey’s test (α=0.05). Results - Regardless of polymerization cycle,no significant difference was observed between the evaluated materials (P=0.38). The highest hardness values (P=0.00003) were obtained when the polymerization cycles were inverted(VCM=48.2>VCB=32.9; VWB=50.5>VWM=24.1). Conclusions - Vipi Cril and Vipi Wave acrylic resins showed hardness values without significant difference after being polymerized according to the manufacturer’s instructions. Higher hardness values were obtained in Vipi Cril microwavepolymerized and in Vipi Wave water-bath polymerized specimens.
Assuntos
Buscar no Google
Índice: LILACS (Américas) Assunto principal: Resinas Acrílicas / Polimetil Metacrilato / Materiais Dentários / Testes de Dureza / Micro-Ondas Tipo de estudo: Ensaio Clínico Controlado Idioma: Português Revista: Rev. ABO nac Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Resinas Acrílicas / Polimetil Metacrilato / Materiais Dentários / Testes de Dureza / Micro-Ondas Tipo de estudo: Ensaio Clínico Controlado Idioma: Português Revista: Rev. ABO nac Assunto da revista: Odontologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR