Your browser doesn't support javascript.
loading
Chromatic spatial contrast sensitivity estimated by visual evoked cortical potential and psychophysics
Brazilian Journal of Medical and Biological Research; Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L..
  • Barboni, M.T.S.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
  • Gomes, B.D.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
  • Souza, G.S.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
  • Rodrigues, A.R.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
  • Ventura, D.F.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
  • Silveira, L.C.L.; Universidade Federal do Pará. Instituto de Ciências Biológicas. Belém. BR
Braz. j. med. biol. res ; 46(2): 154-163, 01/fev. 2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-668780
ABSTRACT
The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Reconhecimento Visual de Modelos / Sensibilidades de Contraste / Potenciais Evocados Visuais Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2013 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Pará/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Reconhecimento Visual de Modelos / Sensibilidades de Contraste / Potenciais Evocados Visuais Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2013 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Pará/BR