Your browser doesn't support javascript.
loading
Esterilização histeroscópica de paciente com dispositivo intrauterino Mirena® / Hysteroscopic sterilization of patient with intrauterine device Mirena®
Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Yatabe, Salete; Lopes, Reginaldo Guedes Coelho.
  • Depes, Daniella De Batista; Hospital do Servidor Público Estadual Francisco Morato de Oliveira. São Paulo. BR
  • Pereira, Ana Maria Gomes; Hospital do Servidor Público Estadual Francisco Morato de Oliveira. São Paulo. BR
  • Yatabe, Salete; Hospital do Servidor Público Estadual Francisco Morato de Oliveira. São Paulo. BR
  • Lopes, Reginaldo Guedes Coelho; Hospital do Servidor Público Estadual Francisco Morato de Oliveira. São Paulo. BR
Einstein (Säo Paulo) ; 11(1): 108-110, jan.-mar. 2013. ilus
Artigo em Português | LILACS | ID: lil-670313
RESUMO
A esterilização tubária é o procedimento definitivo mais utilizado no mundo para controle da fecundidade. A ligadura laparoscópica é segura, porém invasiva e com possíveis riscos cirúrgicos e anestésicos. A via histeroscópica permite a oclusão tubária em ambiente ambulatorial, sem incisões ou anestesia. Um microdispositivo (Essure®) é inserido diretamente no interior das tubas e suas fibras internas de poliéster causam sua obstrução em até 3 meses. Durante esse período, deve ser mantido o método contraceptivo temporário utilizado pela paciente. Várias mulheres utilizam o sistema intrauterino liberador de levonorgestrel, denominado comercialmente Mirena®. O objetivo neste estudo foi de avaliar a possibilidade de inserção do Essure® sem a remoção do dispositivo intrauterino e a tolerância da paciente ao procedimento. O dispositivo foi colocado com sucesso em paciente portadora do Mirena® sem necessidade de retirada do mesmo. Após 3 meses o dispositivo intrauterino foi retirado sem intercorrências.
ABSTRACT
Tubal sterilization is the definitive procedure most often used worldwide to control fecundity. Laparoscopic ligature is safe, but invasive and with possible surgical and anesthetic risks. The hysteroscopic approach enables tubal occlusion at outpatient's setting without the need of incisions or anesthesia. A microdevice (Essure®) is inserted directly into the tubes and its polyethelene fibers cause obstruction of tubes in about three months. During this period, it is recommended that patients continue the use of a temporary birth control method. Several women use the levonorgestrel-releasing intrauterine system, which is called in the market as Mirena®. This report evaluated the possibility of inserting Essure® without remove the intrauterine device; patient tolerance to the procedure was also assessed. The tubal device was successfully placed in the patient without the need to remove Mirena®. After three months the intrauterine device was removed with no intercurrent events.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Esterilização Tubária / Histeroscopia / Dispositivos Intrauterinos Limite: Feminino / Humanos Idioma: Português Revista: Einstein (Säo Paulo) Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital do Servidor Público Estadual Francisco Morato de Oliveira/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Esterilização Tubária / Histeroscopia / Dispositivos Intrauterinos Limite: Feminino / Humanos Idioma: Português Revista: Einstein (Säo Paulo) Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital do Servidor Público Estadual Francisco Morato de Oliveira/BR