Evaluación en dadores de la calidad de extracción de sangre, empleando dos tipos de agujas / Assesment of different equipments for blood donation
Brunner, María Cecilia; Pertecarini, María Gabriela; Brune, Alejandra Beatriz; Reinhardt, Patricia Susana; Tentoni, Juan; Bermúdez, Paula Mariela; Larregina, Norma Alejandra; Polini, Nélida Nora.
  • Brunner, María Cecilia; Hospital Municipal de Agudos Dr. L. Lucero.
  • Pertecarini, María Gabriela; Hospital Municipal de Agudos Dr. L. Lucero.
  • Brune, Alejandra Beatriz; Hospital Municipal de Agudos Dr. L. Lucero.
  • Reinhardt, Patricia Susana; Hospital Municipal de Agudos Dr. L. Lucero.
  • Tentoni, Juan; Hospital Municipal de Agudos Dr. L. Lucero.
  • Bermúdez, Paula Mariela; Hospital Municipal de Agudos Dr. L. Lucero.
  • Larregina, Norma Alejandra; Hospital Municipal de Agudos Dr. L. Lucero.
  • Polini, Nélida Nora; Hospital Municipal de Agudos Dr. L. Lucero.
Rev. argent. transfus ; 36(1): 89-92, 2010. tab, graf
Artigo em Espanhol | LILACS | ID: lil-671834
RESUMEN
Empleando bolsas comerciales Rivero con agujas de fabricación alemana e italiana, se extrajo sangre a 107 sujetos que donaban por primera vez. La población se dividió en dos grupos de forma aleatoria. Las técnicas en hemoterapia interrogaban a cada dador sobre molestias en el sitio de la punción; asimismo evaluaban de forma subjetiva la resistencia a la punción, el arrastre de tejido, las molestias locales, la relación del calibre entre la aguja y la vena y el tiempo de llenado de la bolsa. Utilizando el método de Chi cuadrado, no se observaron diferencias estadísticamente significativas (p> >0,05) en la calidad de los dos tipos de agujas empleadas.
ABSTRACT
Using Rivero commercial bags with Italian or German needles, blood samples were taken from 107 first time donors. This population was divided randomly into two groups. The nurses inquired each donor about discomfort at the punction site. Likewise evaluated subjectively for resistance to puncture. tissue drag, local discomfort, needle size to vein ratio and bag filling time. Using the Chi-square method, no statistically significant differences were found (p> >0.05) on the quality of both two types of needles.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Controle de Qualidade / Doadores de Sangue / Agulhas Tipo de estudo: Ensaio Clínico Controlado Limite: Humanos Idioma: Espanhol Revista: Rev. argent. transfus Assunto da revista: Hematologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Argentina

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Controle de Qualidade / Doadores de Sangue / Agulhas Tipo de estudo: Ensaio Clínico Controlado Limite: Humanos Idioma: Espanhol Revista: Rev. argent. transfus Assunto da revista: Hematologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Argentina