Your browser doesn't support javascript.
loading
Contaminação das resinas compostas em clínicas de instituição de ensino / Contamination in composite resins from dental clinics of university
Werle, Stefanie Bressan; Santos, Roberto Christ Vianna; Dotto, Patrícia Pasquali.
  • Werle, Stefanie Bressan; Universidade Federal de Santa Maria. Santa maria. BR
  • Santos, Roberto Christ Vianna; Centro Universitário Franciscano. Santa Maria. BR
  • Dotto, Patrícia Pasquali; Centro Universitário Franciscano. Santa Maria. BR
Artigo em Português | LILACS, BBO | ID: lil-673928
RESUMO

Objetivo:

Avaliar, por meio de análise microbiológica, a contaminação nas resinas compostas utilizadas em clínicas odontológicas de uma Instituição de Ensino na cidade de Santa Maria, RS, Brasil.

Método:

Foi realizado um levantamento quanto ao número de acadêmicos que utilizam cada clínica, bem como o semestre à qual pertenciam. Um total de 100 amostras estavam disponíveis para a análise nas 3 diferentes clínicas. Incrementos de 2 mm foram removidos de cada tubete de resina composta disponível de forma asséptica e imersos em 5ml do meio de cultura BHI (Brain Heart Infusion). Após 24 horas de incubação em estufa bacteriológica à 37ºC foi feita a primeira leitura, e após 48 horas, a última. Um grupo controle negativo para o meio de cultura foi realizado. As amostras nas quais ocorreu o turvamento do meio de cultura foram consideradas contaminadas.

Resultados:

51% das amostras analisadas encontravam-se contaminadas, apresentando variação do percentual de ocorrência entre as clínicas incluídas.

Conclusão:

Em algum momento do procedimento restaurador, executado pelos acadêmicos, ocorre uma falha geradora da contaminação. Assim, há risco de infecção cruzada, havendo a necessidade de buscar alternativas para barrar essa contaminação durante o procedimento.
ABSTRACT

Purpose:

The aim of this study was to assess microbiologically the composite resins used in dental clinics of a University in Santa Maria, RS, Brazil.

Method:

Were analyze a total of 100 samples available in 3 different clinics. Increments of 2 mm were removed from the tubes of resin and cultured in 5 ml of BHI (Brain Heart Infusion). After 24 hours of incubation in a bacteriological incubator at 37°C, was made the first analysis, and after 48 hours, the last one. A negative control group for the method was performed. The samples on which turbidity was found were considered contaminated.

Results:

The contamination was present in 51% of composite resins analyzed, showing a difference in the incidence between clinics.

Conclusion:

In the restorative procedure, performed by students, there is a fail wich generates contamination. This failure has potential to cause crossed infection. Thus shows the need of search for alternatives to prevent the contamination during the procedure.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resinas Compostas / Contaminação Biológica / Materiais Dentários País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário Franciscano/BR / Universidade Federal de Santa Maria/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resinas Compostas / Contaminação Biológica / Materiais Dentários País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: Odontologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário Franciscano/BR / Universidade Federal de Santa Maria/BR