Your browser doesn't support javascript.
loading
Evaluación de la seguridad de una suspensión de fosfato de cromo(III) para uso en radiosinoviortesis / Evaluation of the safety a Chromium (III) Phosphate suspension for radiosynoviorthesis
Cruz Arencibia, Jorge; Cruz Morales, Amed; Tamayo Fuente, Radamés; García Rodríguez, Enrique; Alberdi Oquendo, Leydis; Morín Zorrilla, José.
  • Cruz Arencibia, Jorge; Centro de isótopos. Mayabeque. CU
  • Cruz Morales, Amed; Centro de isótopos. Mayabeque. CU
  • Tamayo Fuente, Radamés; Centro de isótopos. Mayabeque. CU
  • García Rodríguez, Enrique; Centro de isótopos. Mayabeque. CU
  • Alberdi Oquendo, Leydis; Centro de isótopos. Mayabeque. CU
  • Morín Zorrilla, José; Centro de isótopos. Mayabeque. CU
Rev. cuba. farm ; 47(1): 29-40, ene.-mar. 2013.
Artigo em Espanhol | LILACS | ID: lil-674108
RESUMEN

Objetivo:

evaluar la fuga de radiactividad de la cavidad articular después de la administración de suspensiones radiomarcadas de Fosfato de Cromo(III) y la probabilidad de inducción de genotoxicidad.

Métodos:

las suspensiones se obtuvieron según método reportado. Para la evaluación de la fuga articular las suspensiones marcadas se administraron por vía intraarticular en ratas y conejos. El seguimiento se realizó por medición de la actividad retenida por cámara gamma. En los estudios de genotoxicidad se determinó la frecuencia de formación de micronúcleos en eritrocitos de médula ósea de ratas para 2 dosis y 2 tiempos para cada preparado.

Resultados:

para las suspensiones radiomarcadas en estudio la fuga fue no significativa durante 3 semanas (< 3 por ciento para la marcada con 51Cr y ~5 por ciento con 32P). Para los preparados con 32P e 90Y se observó poca diferencia en la frecuencia de aparición de micronúcleos para el 1-er tiempo, independientemente de las dosis administradas. A tiempos mayores se produjo un incremento en la formación de micronúcleos para las dosis superiores.

Conclusiones:

se demostró la posibilidad del uso seguro de una suspensión de Fosfato de Cromo(III) marcada con diferentes radionúclidos, en particular que la fuga articular de la suspensión no fue significativa durante 3 semanas y se comprobó las ventajas de tener un preparado con mayor tamaño de partículas. Para las suspensiones marcadas con 90Y y 32P no se producen incrementos en la frecuencia de formación de micronúcleos para una dosis superior en aproximadamente 40 veces a la prevista a utilizar en la clínica
ABSTRACT

Objective:

to evaluate the leakage of radioactivity after intraarticular administration of radioactive suspensions based on Chromium (III) Phosphate as well as the probability of induction of genotoxic effect.

Methods:

the suspensions were obtained in line with the published procedure. For the articular leakage evaluation, the radioactive suspensions were intraarticulary administered in rats and rabbits. The radioactivity retention was measured by gamma chamber. A comparison with commercial radiopharmaceutical labeled with 32P was made. The genotoxicity studies determined the frequency of micronuclei formation in the rats´ bone marrow erythrocytes by using 2 doses and 2 time intervals for each preparation.

Results:

the radiolabeled suspensions under evaluation showed that the leakage was not significant during 3 weeks (<3 percent for the suspension labeled with 51Cr and ~5 percent in the one labeled with 32P) and the advantages of having larger particle preparation were confirmed. For those suspension labeled with 32P and 90Y , no significant difference was seen in the frequency of micronuclei formation for the first time interval, regardless of the administered doses. The micronuclei formation increased for higher doses and at longer time intervals.

Conclusions:

the results demonstrated the possibility of the safe use of a of Chromium (III) Phosphate suspension labeled with several radionuclides for the treatment of different joints, in particular the leakage was not significant during 3 weeks and the advantages of having a larger particle radiopharmaceutical was confirmed. For the suspensions labeled with 32P and 90Y micronucleus frequency mildly increased with the time and administered doses
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Artrite Reumatoide / Sinovite / Radioisótopos de Cromo Idioma: Espanhol Revista: Rev. cuba. farm Assunto da revista: Farmácia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Centro de isótopos/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Artrite Reumatoide / Sinovite / Radioisótopos de Cromo Idioma: Espanhol Revista: Rev. cuba. farm Assunto da revista: Farmácia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Centro de isótopos/CU