Análise de medidas lineares da mandíbula em modelos tridimensionais reformatados a partir da tomografia computadorizada de feixe cônico / Mandibular linear measurements on 3D CBCT models
Bauru; s.n; 2012. 113 p. tab, graf.
Tese em Português | LILACS, BBO | ID: lil-681476
RESUMO
Avaliar a precisão e a acurácia de medidas lineares da mandíbula em modelos tridimensionais gerados a partir da tomografia computadorizada de feixe cônico (TCFC) em dois programas (Dolphin®. Material e Métodos: Dez mandíbulas com marcadores de sílica foram submetidas à TCFC seguindo o protocolo de voxel 0,3 mm do aparelho i-CAT Classic®. Vinte medidas lineares foram realizadas duas vezes, de maneira aleatória, nos modelos tridimensionais nos programas Dolphin®, nos filtros Translúcido e Sólido-1, e InVesalius®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas por um segundo examinador. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse, teste de Bland-Altman e erro absoluto e percentual foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Alta precisão foi encontrada no programa Dolphin®, filtro Translúcido e Sólido-1 e InVesalius®, com diferença máxima entre as mensurações de 0,27; 0,26 e 0,17 mm, respectivamente. Com relação à acurácia, 10 variáveis no filtro Translúcido; oito no filtro Sólido-1 e 13 no programa inVesalius® foram diferentes estatisticamente em relação as medidas físicas. Porém, 95%, 100% e 90% das medidas apresentaram valores abaixo do valor considerado clinicamente relevante (1 mm) nos filtros Translúcido e Sólido-1 e no programa InVesalius®, respectivamente. Conclusão: Os modelos tridimensionais com marcadores hiperdensos, gerados pelos programas Dolphin®, filtro Translúcido e Sólido-1, e InVesalius® podem ser utilizados com precisão e acurácia para a obtenção de medidas lineares.
ABSTRACT
The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different software (Dolphin® and InVesalius®). Methods: Ten dry human mandibles were scanned at voxel size of 0.3 mm (i-CAT Classic®). Twenty measurements were made twice, randomized, on 3D model generated by the software Dolphin (filter Translucent and Solid-1) and InVesalius. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) BlandAltman, absolute and percentage mean error were used for evaluating accuracy and reliability (p<0.05). Results: Excellent reliability values were found for linear measurements from CBCT volume rendering images in all methods (Dolphin Translucent, Solid-1 and InVesalius), with the mean measurement of 0.27; 0.26 and 0.17 mm, respectively. Ten measurement errors for Dolphin Translucent, eight for Solid-1 and 13 for InVesalius were statistically significant different from physical measurements; however, 95%, 100% and 90% of the measurements were, respectively, below the value clinically relevant (1 mm). Conclusion: Linear measurements on 3D model generated by the software Dolphin (Translucent and Solid-1) and InVesalius are reliable and accurate and can be used for linear measurements.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Cefalometria / Imageamento Tridimensional / Tomografia Computadorizada de Feixe Cônico / Mandíbula Tipo de estudo: Ensaio Clínico Controlado / Guia de Prática Clínica / Estudo prognóstico Limite: Humanos Idioma: Português Ano de publicação: 2012 Tipo de documento: Tese

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Cefalometria / Imageamento Tridimensional / Tomografia Computadorizada de Feixe Cônico / Mandíbula Tipo de estudo: Ensaio Clínico Controlado / Guia de Prática Clínica / Estudo prognóstico Limite: Humanos Idioma: Português Ano de publicação: 2012 Tipo de documento: Tese