RESUMO

OBJETIVO:

Avaliar a biocompatibilidade de material FullCure 720®, que é uma resina, na confecção de implante orbitário. Avaliou-se a resposta clínica dos animais, toxicidade sistêmica e a resposta inflamatória crônica. Os animais foram pesados, exames bioquímicos e resposta inflamatória foram avaliados. Foi efetuada evisceração e colocado implante esférico orbitário. Os animais foram acompanhados durante o período de 60 dias, onde se avaliou o comportamento clínico e sinais locais. Após este período, procedeu-se a eutanásia seguida da enucleação. Foi realizada análise macroscópica e histomorfométrica. Os resultados revelaram comportamento normal dos animais, com ausência de exposição ou extrusão dos implantes, morte de algum animal e ausência de toxicidade sistêmica. Houve formação de uma cápsula fibrosa entre a capa escleral e o implante orbitário, resposta inflamatória considerada normal quando em contato com o tecido do coelho. A resina FullCure 720® utilizada como implante orbitário, mostrou-se biocompatível neste estudo.
ABSTRACT

PURPOSE:

To evaluate the resin FullCure 720® biocompatibility as orbital implant. Clinical response and signs of systemic toxicity to the resin were evaluated, local biocompatibility and microscopic analysis regarding chronic local inflammatory response to the implant. The animals were weighted, biochemical exams and inflammatory response were evaluated. All animals were eviscerated and implantation of the spheres was carried out. Animals were followed for 60 days. Clinical behavior of animals and local signals of inflammation had been observed. After this period animals underwent euthanasia followed by enucleation. Macroscopic and histomorphometric analysis were performed. The results showed normal behavior of the animals, without implant exposure, extrusion, death or systemic toxicity. Capsule tissue formation was observed between the sclera and the implant. Normal inflammatory response to the foreign material in contact with the rabbit soft tissue was observed. The resin FullCure 720®, demonstrated to be biocompatible as an orbital implant in this study.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Materiais Biocompatíveis / Resinas Acrílicas / Teste de Materiais / Implantes Orbitários Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade Evangélica do Paraná/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Materiais Biocompatíveis / Resinas Acrílicas / Teste de Materiais / Implantes Orbitários Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade Evangélica do Paraná/BR