Your browser doesn't support javascript.
loading
Comparação entre a Dopplermetria e o fluxo livre da artéria torácica interna de cães com e sem o uso de noradrenalina / Comparison between the Doppler flowmetry and the free flow of dog's internal thoracic artery with and without use norepinephrine
Bordinhão, Alessandro.
  • Bordinhão, Alessandro; Hospital Universitário Evangélico de Curitiba.
Rev. bras. cir. cardiovasc ; 28(2): 224-230, abr.-jun. 2013. tab
Artigo em Português | LILACS | ID: lil-682433
RESUMO
OBJETIVO: Este trabalho objetiva estudar comparativamente o fluxo livre e a dopplerfluxometria da artéria torácica interna de cães anestesiados com e sem a administração de noradrenalina endovenosa contínua. MÉTODOS: A amostra foi constituída de 10 cães mestiços, nos quais foram dissecadas as artérias torácicas internas direita e esquerda e avaliado seu fluxo; primeiramente, pela dopplerfluxometria e depois pelo fluxo livre. Foram registrados a pressão arterial média e o diâmetro das artérias no início do procedimento. As verificações do fluxo pelos dois métodos ocorreram em três tempos: tempo zero, 10 e 25 minutos. Após a primeira verificação no tempo zero, iniciou-se a infusão contínua de noradrenalina no átrio direito; as avaliações aos 10 e 25 minutos foram feitas da mesma forma que na primeira vez, nas mesmas artérias e pelos dois métodos, anotando-se os resultados, assim como a pressão arterial média correspondente. RESULTADOS: Os resultados da verificação de fluxo, entre Dopplermetria e fluxo livre, apresentaram-se similares; sendo os primeiros, nos tempos zero, 10 e 25 minutos, respectivamente, 183, 237 e 230,1 ml/min, comparados aos segundos, 168,6, 226,8 e 226,4 ml/min (P=0,285). A média das pressões arteriais dos três tempos e o diâmetro médio das artérias não apresentaram diferenças estatisticamente significativas entre os métodos, portanto, não influenciaram na comparação dos resultados. CONCLUSÃO: As avaliações, tanto da dopplerfluxometria quanto do fluxo livre, foram semelhantes nos três tempos verificados.
ABSTRACT
OBJECTIVE: This work aims to study comparatively the free flow and the Doppler flowmetry of the internal thoracic artery in anesthetized dogs, with and without continuous intravenous administration of norepinephrine. METHODS: The sample was made up of ten mongrel dogs, which dissected the left and right internal thoracic arteries and evaluated your stream; first, by Doppler flowmetry and then by free flow. The mean arterial pressure and the diameter of the arteries at the beginning of the procedure were registered. The workflow checks by two methods occurred in three times: time zero, 10 and 25 minutes. After the first check in time zero, the continuous infusion of norepinephrine in the right atrium; other checks were made in the same way that the first time, to 10 and 25 minutes, in the same arteries and by two methods, each one in his artery, noting the results, as well as the corresponding average blood pressure. RESULTS: The results of the scan of the stream, between Doppler flowmetry and free flow, there were similar; being the first, zero times, ten and twenty-five minutes, respectively, 183, 230.1 and 237 ml/min compared to seconds, 168.6, 226.8 and 226.4 ml/min (P = 0.285). The mean arterial pressures of three times and the average diameter of the arteries, showed no statistically significant differences between the methods, so did not influence on the comparison of the results. CONCLUSION: The evaluations, both from Doppler flowmetry and free flow, were similar in three times checked.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fluxo Sanguíneo Regional / Vasoconstritores / Norepinefrina / Fluxometria por Laser-Doppler / Artéria Torácica Interna Limite: Animais Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fluxo Sanguíneo Regional / Vasoconstritores / Norepinefrina / Fluxometria por Laser-Doppler / Artéria Torácica Interna Limite: Animais Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil