Evaluación de la resistencia a la tensión entre diferentes sistemas de pernos intrarradiculares: estudio in vitro / Evaluation of tensile strength between different intraradicular bolt systems: in vitro study
Acta odontol. venez
;
48(3)2010.
Artigo
em Espanhol
| LILACS
| ID: lil-682905
RESUMEN
La reconstrucción de los dientes tratados endodónticamente juega un papel importante en el pronóstico, ya que el 60% de los fracasos endodónticos se relacionan con la rehabilitación. Diversos sistemas y materiales se han utilizado en la reconstrucción de los dientes, alternando el diseño, material del perno, agente cementante y el tipo de muñón utilizado, evidenciando resultados contradictorios. Evaluar la resistencia a la tensión (RT) entre tres diferentes sistemas de pernos intrarradiculares. Se incluyeron 45 premolares monorradiculares, los cuales fueron instrumentados y preparados para ser reconstruidos con diversos sistemas de pernos. Estos fueron divididos en tres grupos 1.-Sistema Perno-Muñón Colado (PMC), 2.-Sistema Para-Post Acero (PPA) y 3.-Sistema Para-Post Fiber-Lux (PPFL), cementados uniformemente con un cemento resinoso y sometido a RT en una máquina Instrom. La máxima RT fue para el sistema PMC (11.11 Mp), seguido por PPFL (3.42 Mp) y PPA con (3.14 Mp). La prueba de ANOVA complementada con el Post-Hoc DSH de Tukey reveló diferencias significativas entre PMC vs PPA y PPFL (p<0.05), entre PPA vs PPFL no hubo diferencias significativas. Ningún sistema prefabricado se desalojó a la prueba de tensión y los muñones se fracturaron. El sistema de PMC registró mayor RT que los sistemas PPA y PPFL (p<0.05) entre los prefabricados no existieron diferencias significativas
ABSTRACT
The reconstruction of teeth endodontically treated represents an important role, since the 60% of the endodontic failures relate to the rehabilitation. Diverse technical and material they have been utilized in the reconstruction of the posts, alternating the design, material, luting agent and the type of core utilized, showing contradictory results. Evaluating the tensional resistance (TR) of three post-endodontical reconstruction systems.Forty-five human premolars were used for this study, which were instrumented and prepared for receiving a post. They were divided into three groups l. - casted post and core system (CPC), 2. - Steel Para-Post system (SPP) and 3. - Para-Post Fiber-Lux system (PPFL), which they were cemented with resinous cement and submitted to TR in Instrom machine. The maximum TR was for CPC (11.11 Mp), followed by PPFL (3.42 Mp) and SPP with (3.14 Mp). The ANOVA test supplemented with Post-Hoc HSD de Tukey´s revealed statistically differences significantly between CPC vs SPP and PPFL (p<0.05), among SPP vs PPFL do not there was statistically differences significantly. The prefabricated post, not there was dislocated and the cores were fractured. The CPC registered the higher TR that the prefabricated post (p<0.05) and among the prefabricated post did not exist differences significantly
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Técnicas In Vitro
/
Técnica para Retentor Intrarradicular
/
Cimentos de Resina
/
Endodontia
Limite:
Humanos
Idioma:
Espanhol
Revista:
Acta odontol. venez
Assunto da revista:
Medicina Bucal
/
Odontologia
/
Sa£de Bucal
Ano de publicação:
2010
Tipo de documento:
Artigo
País de afiliação:
México
Instituição/País de afiliação:
Universidad de Guadalajara/MX
Similares
MEDLINE
...
LILACS
LIS