Your browser doesn't support javascript.
loading
Ablação de arritmias por cateter com mapeamento eletroanatômico exclusivo: uma série de casos / Catheter ablation of arrhythmias exclusively using electroanatomic mapping: a series of cases
Pires, Leonardo Martins; Leiria, Tiago Luiz Luz; Kruse, Marcelo Lapa; Ronsoni, Rafael; Gensas, Caroline Saltz; Lima, Gustavo Glotz de.
  • Pires, Leonardo Martins; Instituto de Cardiologia/Fundação Universitária de Cardiologia. Porto Alegre. BR
  • Leiria, Tiago Luiz Luz; Instituto de Cardiologia/Fundação Universitária de Cardiologia. Porto Alegre. BR
  • Kruse, Marcelo Lapa; Instituto de Cardiologia/Fundação Universitária de Cardiologia. Porto Alegre. BR
  • Ronsoni, Rafael; Instituto de Cardiologia/Fundação Universitária de Cardiologia. Porto Alegre. BR
  • Gensas, Caroline Saltz; Instituto de Cardiologia/Fundação Universitária de Cardiologia. Porto Alegre. BR
  • Lima, Gustavo Glotz de; Instituto de Cardiologia/Fundação Universitária de Cardiologia. Porto Alegre. BR
Arq. bras. cardiol ; 101(3): 226-232, set. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-686538
RESUMO
FUNDAMENTO: A ablação por cateter possibilita tratamento curativo para diversas arritmias cardíacas. A fluoroscopia é utilizada para localizar e direcionar os cateteres aos pontos causadores de arritmias. Contudo, a fluoroscopia apresenta diversos riscos. O mapeamento eletroanatômico (MEA) apresenta imagem tridimensional sem utilizar raios X, reduzindo os riscos da fluoroscopia. OBJETIVO: Descrevemos uma série de pacientes nos quais foi realizada ablação de arritmias cardíacas com o uso exclusivo de MEA. MÉTODOS: Foram selecionados prospectivamente, de março de 2011 a março de 2012, pacientes com arritmias cardíacas refratárias ao tratamento farmacológico para realização de ablação de arritmias com o uso exclusivo de MEA. Não participaram aqueles com indicação de estudo eletrofisiológico diagnóstico e ablação de fibrilação atrial, taquiarritmias de átrio esquerdo e arritmia ventricular hemodinamicamente instável. Observamos tempo total de procedimento, taxa de sucesso, complicações e se ocorreu necessidade de uso de fluoroscopia durante o procedimento. RESULTADOS: Participaram 11 pacientes, sendo sete do sexo feminino (63%), com idade média de 50 anos (DP ± 16,5). As indicações dos procedimentos foram quatro casos (35%) de flutter atrial, três casos (27%) de síndrome de pré-excitação, dois casos (19%) de taquicardia supraventricular paroxística e dois casos (19%) de extrassístoles ventriculares. A média de duração do procedimento foi de 86,6 min (DP ± 26 min). O sucesso imediato (na alta hospitalar) do procedimento ocorreu em nove pacientes (81%). Não houve complicações durante os procedimentos. CONCLUSÃO: Neste estudo, foi demonstrado que é viável a realização de ablação de arritmias apenas com o uso do MEA, com resultados satisfatórios.
ABSTRACT
BACKGROUND: Catheter ablation is a treatment that can cure various cardiac arrhythmias. Fluoroscopy is used to locate and direct catheters to areas that cause arrhythmias. However, fluoroscopy has several risks. Electroanatomic mapping (EAM) facilitates three-dimensional imaging without X-rays, which reduces risks associated with fluoroscopy. OBJECTIVE: We describe a series of patient cases wherein cardiac arrhythmia ablation was exclusively performed using EAM. METHODS: Patients who presented with cardiac arrhythmias that were unresponsive to pharmacological therapy were prospectively selected between March 2011 and March 2012 for arrhythmia ablation exclusively through EAM. Patients with indications for a diagnostic electrophysiology study and ablation of atrial fibrillation, left atrial tachyarrhythmias as well as hemodynamically unstable ventricular arrhythmia were excluded. We documented the procedure time, success rate and complications as well as whether fluoroscopy was necessary during the procedure. RESULTS: In total, 11 patients were enrolled in the study, including seven female patients (63%). The mean age of the patients was 50years (SD ±16.5). Indications for the investigated procedures included four cases (35%) of atrial flutter, three cases (27%) of pre-excitation syndrome, two cases (19%) of paroxysmal supraventricular tachycardia and two cases (19%) of ventricular extrasystoles. The mean procedure duration was 86.6 min (SD ± 26 min). Immediate success (at discharge) of the procedure was evident for nine patients (81%). There were no complications during the procedures. CONCLUSION: This study demonstrates the feasibility of performing an arrhythmia ablation exclusively using EAM with satisfactory results.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Arritmias Cardíacas / Ablação por Cateter Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Universitária de Cardiologia+BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Arritmias Cardíacas / Ablação por Cateter Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Universitária de Cardiologia+BR