Your browser doesn't support javascript.
loading
Infrared Thermometer: an accurate tool for temperature measurement during renal surgery
Marchini, Giovanni Scala; Duarte, Ricardo Jordao; Mitre, Anuar Ibrahim; Tiseo, Bruno Camargo; Cassao, Valter Dell'Acqua; Torricelli, Fabio Cesar Miranda; Arap, Marco Antonio; Srougi, Miguel.
  • Marchini, Giovanni Scala; s.af
  • Duarte, Ricardo Jordao; s.af
  • Mitre, Anuar Ibrahim; s.af
  • Tiseo, Bruno Camargo; s.af
  • Cassao, Valter Dell'Acqua; s.af
  • Torricelli, Fabio Cesar Miranda; s.af
  • Arap, Marco Antonio; s.af
  • Srougi, Miguel; s.af
Int. braz. j. urol ; 39(4): 572-578, Jul-Aug/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-687300
ABSTRACT
Purpose To evaluate infrared thermometer (IRT) accuracy compared to standard digital thermometer in measuring kidney temperature during arterial clamping with and without renal cooling. Materials and Methods 20 pigs weighting 20Kg underwent selective right renal arterial clamping, 10 with (Group 1 - Cold Ischemia with ice slush) and 10 without renal cooling (Group 2 - Warm Ischemia). Arterial clamping was performed without venous clamping. Renal temperature was serially measured following clamping of the main renal artery with the IRT and a digital contact thermometer (DT): immediate after clamping (T0), after 2 (T2), 5 (T5) and 10 minutes (T10). Temperature values were expressed in mean, standard deviation and range for each thermometer. We used the T student test to compare means and considered p < 0.05 to be statistically significant. Results In Group 1, mean DT surface temperature decrease was 12.6 ± 4.1°C (5-19°C) while deep DT temperature decrease was 15.8 ± 1.5°C (15-18°C). For the IRT, mean temperature decrease was 9.1 ± 3.8°C (3-14°C). There was no statistically significant difference between thermometers. In Group 2, surface temperature decrease for DT was 2.7 ± 1.8°C (0-4°C) and mean deep temperature decrease was 0.5 ± 1.0°C (0-3°C). For IRT, mean temperature decrease was 3.1 ± 1.9°C (0-6°C). No statistically significant difference between thermometers was found at any time point. conclusions IRT proved to be an accurate non-invasive precise device for renal temperature monitoring during kidney surgery. External ice slush cooling confirmed to be fast and effective at cooling the pig model. IRT = Infrared thermometer DT = Digital contact thermometer D:S = Distance-to-spot ratio .
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Termômetros / Temperatura Corporal / Raios Infravermelhos / Rim Tipo de estudo: Estudos de avaliação / Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Int. braz. j. urol Assunto da revista: Urologia Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Termômetros / Temperatura Corporal / Raios Infravermelhos / Rim Tipo de estudo: Estudos de avaliação / Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Int. braz. j. urol Assunto da revista: Urologia Ano de publicação: 2013 Tipo de documento: Artigo