Your browser doesn't support javascript.
loading
Adequação do dispositivo intrauterino pela avaliação ultrassonográfca: inserção pós-parto e pós-abortamento versus inserção durante o ciclo menstrual / Adequacy of the device intrauterine by ultrasound evaluation: postpartum and post-abortion insertion versus insertion during the menstrual cycle
Holanda, Antônio Arildo Reginaldo de; Pessoa, Aline de Melo; Holanda, Julita de Campos Pipolo; Melo, Maria Helena Vieira de; Maranhão, Técia Maria de Oliveira.
  • Holanda, Antônio Arildo Reginaldo de; Universidade Federal do Rio Grande do Norte. Maternidade Escola Januário Cicco. Natal. BR
  • Pessoa, Aline de Melo; Universidade Federal do Rio Grande do Norte. Maternidade Escola Januário Cicco. Natal. BR
  • Holanda, Julita de Campos Pipolo; Universidade Federal do Rio Grande do Norte. Maternidade Escola Januário Cicco. Natal. BR
  • Melo, Maria Helena Vieira de; Universidade Federal do Rio Grande do Norte. Maternidade Escola Januário Cicco. Natal. BR
  • Maranhão, Técia Maria de Oliveira; Universidade Federal do Rio Grande do Norte. Maternidade Escola Januário Cicco. Natal. BR
Rev. bras. ginecol. obstet ; 35(8): 373-378, Aug. 2013. tab
Artigo em Português | LILACS | ID: lil-688698
RESUMO
OBJETIVO: Comparar, empregando a ultrassonografia transvaginal, a adequação da posição do dispositivo intrauterino (DIU) na cavidade uterina, em função do período: inserção pós-parto e pós-aborto versus inserção durante o ciclo menstrual. MÉTODOS: Estudo epidemiológico do tipo individuado, observacional e transversal, realizado entre fevereiro e julho de 2013. Foram incluídas 290 mulheres, sendo 205 com inserção no ciclo menstrual e 85 no pós-abortamento/pós-parto. As variáveis independentes foram: idade, paridade, tempo de uso, época de inserção, número de retornos ao planejamento familiar, satisfação com o método, desejo de continuidade, queixas e complicações. A variável dependente foi a adequação do DIU na cavidade uterina. Para a análise estatística empregou-se o teste do χ², com correção de Pearson, e o teste exato de Fisher, considerando um nível de significância de 5%. RESULTADOS: A idade média foi de 29,4 anos e o tempo médio de uso foi de 2,7 anos; 39,3% das mulheres tiveram queixas associados ao método, sendo a menorragia a mais frequente (44,7%). A satisfação foi de 85%, e 61,4% retornaram duas ou mais vezes para consultas. A faixa etária, a paridade e a posição do útero não se associaram com má adequação do DIU na cavidade uterina (p>0,05). A inserção no ciclo menstrual associou-se mais à posição adequada do DIU do que a inserção pós-parto/pós-abortamento, com significância estatística (p=0,028). CONCLUSÃO: A inserção no pós-parto e pós-abortamento apresentaram piores resultados quanto à adequação do DIU, não sendo observado o mesmo com a faixa etária, a paridade e a posição do útero na cavidade pélvica.
ABSTRACT
PURPOSE: To compare by transvaginal ultrasound the position of the intrauterine device (IUD) inside the uterine cavity, depending on the time of insertion, postpartum and post-abortion, and during the menstrual cycle. METHODS: Epidemiologic, observational and cross-sectional study carried out between February and July, 2013. A total of 290 women were included, 205 of them with insertion during the menstrual cycle and 85 during the postpartum and post-abortion periods. The independent variables were: age, parity, time of use, insertion time, number of returns to family planning, satisfaction with the method, wish to continue using the device, symptoms and complications. The dependent variable was the adequate position of the IUD inside the uterine cavity. The χ² test with Pearson's correction and the Fisher exact test were used for statistical analysis, with the level of significance set at 5%. RESULTS: The average age was 29.4 years and the average time of IUD use was 2.7 years; 39.3% of the women had symptoms associated with the method, the most frequent being menorrhagia (44.7%). The degree of satisfaction was 85% and 61.4% of the women returned two or more times for consultation about family planning. Age, parity and the position of the uterus in the pelvic cavity was not associated with a poor position of the IUD inside the uterine cavity (p>0.05). Insertion during the menstrual cycle was significantly more associated with a correct position of the IUD than postpartum and post-abortion insertion (p<0.028). CONCLUSION: Postpartum and post-abortion insertion showed worse results regarding the adequacy of IUD position, a fact that was not observed regarding age, parity or position of the uterus in the pelvic cavity.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Útero / Dispositivos Intrauterinos Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Adolescente / Adulto / Feminino / Humanos Idioma: Português Revista: Rev. bras. ginecol. obstet Assunto da revista: Ginecologia / Obstetrícia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio Grande do Norte/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Útero / Dispositivos Intrauterinos Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Adolescente / Adulto / Feminino / Humanos Idioma: Português Revista: Rev. bras. ginecol. obstet Assunto da revista: Ginecologia / Obstetrícia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio Grande do Norte/BR