Biomechanical comparison of the four-strand cruciate and Strickland techniques in animal tendons
Iamaguchi, Raquel Bernardelli; Villani, William; Rezende, Marcelo Rosa; Wei, Teng Hsiang; Cho, Alvaro B.; Santos, Gustavo Bispo dos; Mattar Jr, Rames.
  • Iamaguchi, Raquel Bernardelli; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
  • Villani, William; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
  • Rezende, Marcelo Rosa; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
  • Wei, Teng Hsiang; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
  • Cho, Alvaro B.; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
  • Santos, Gustavo Bispo dos; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
  • Mattar Jr, Rames; Universidade de Sao Paulo. Faculdade de Medicina. Institute of Orthopedics and Traumatology. Sao Paulo. BR
Clinics ; 68(12): 1543-1547, dez. 2013. graf
Artigo em Inglês | LILACS | ID: lil-697709
ABSTRACT
OBJECTIVE: The objective of this study was to compare two four-strand techniques: the traditional Strickland and cruciate techniques. METHODS: Thirty-eight Achilles tendons were removed from 19 rabbits and were assigned to two groups based on suture technique (Group 1, Strickland suture; Group 2, cruciate repair). The sutured tendons were subjected to constant progressive distraction using a universal testing machine (Kratos®). Based on data from the instrument, which were synchronized with the visualized gap at the suture site and at the time of suture rupture, the following data were obtained: maximum load to rupture, maximum deformation or gap, time elapsed until failure, and stiffness. RESULTS: In the statistical analysis, the data were parametric and unpaired, and by Kolmogorov-Smirnov test, the sample distribution was normal. By Student's t-test, there was no significant difference in any of the data: the cruciate repair sutures had slightly better mean stiffness, and the Strickland sutures had longer time-elapsed suture ruptures and higher average maximum deformation. CONCLUSIONS: The cruciate and Strickland techniques for flexor tendon sutures have similar mechanical characteristics in vitro. .
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Traumatismos dos Tendões / Tendões / Técnicas de Sutura Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de Sao Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Traumatismos dos Tendões / Tendões / Técnicas de Sutura Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Clinics Assunto da revista: Medicina Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de Sao Paulo/BR