Your browser doesn't support javascript.
loading
Bismuth subsalicylate as filler particle for an experimental epoxy-based root canal sealer
Schwartzer, Eduardo; Genari, Bruna; Collares, Fabrício Mezzomo; Leitune, Vicente Castelo Branco; Ogliari, Fabrício Aulo; Samuel, Susana Maria Werner.
  • Schwartzer, Eduardo; Federal University of Rio Grande do Sul. School of Dentistry. Dental Materials Laboratory. Porto Alegre. BR
  • Genari, Bruna; Federal University of Rio Grande do Sul. School of Dentistry. Dental Materials Laboratory. Porto Alegre. BR
  • Collares, Fabrício Mezzomo; Federal University of Rio Grande do Sul. School of Dentistry. Dental Materials Laboratory. Porto Alegre. BR
  • Leitune, Vicente Castelo Branco; Federal University of Rio Grande do Sul. School of Dentistry. Dental Materials Laboratory. Porto Alegre. BR
  • Ogliari, Fabrício Aulo; Federal University of Rio Grande do Sul. School of Dentistry. Dental Materials Laboratory. Porto Alegre. BR
  • Samuel, Susana Maria Werner; Federal University of Pelotas. School of Engineering. Porto Alegre. BR
Braz. j. oral sci ; 12(3): 173-177, July-Sept. 2013. graf, tab
Artigo em Inglês | LILACS | ID: lil-701302
ABSTRACT

AIM:

To evaluate the influence of bismuth subsalicylate addition in different concentrations on theproperties ofan experimental epoxy-based root canal sealer.

METHODS:

Bismuth subsalicylate in 20%, 40%, 60%, 80%, 100% and 120 wt% was added tothe sealer. Flow, film thickness, working time, setting time, dimensional change, sorption, solubility and cytotoxicity were evaluated according to ISO standard. Data were statistically analyzed by one-way ANOVA and Tukey'stest with a significance level of 5% for all tests.

RESULTS:

The flow, working and setting times significantly decreased withincreasing particle concentration. The film thickness, dimensional change, water sorption and solubility values significantly increased with higher particle amount. The results for cytotoxicity showed no statistically significant differences among the particle proportions.

CONCLUSIONS:

The results suggest that the addition up to 80% wt of bismuth subsalicylate appears to be a promising filler particle to root canal sealer development.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Bismuto / Cavidade Pulpar / Endodontia / Antiácidos Limite: Humanos Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Pelotas/BR / Federal University of Rio Grande do Sul/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Bismuto / Cavidade Pulpar / Endodontia / Antiácidos Limite: Humanos Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Pelotas/BR / Federal University of Rio Grande do Sul/BR