Your browser doesn't support javascript.
loading
Changes in root canal anatomy using three nickel-titanium rotary system: a cone beam computed tomography analysis
Aguiar, Carlos Menezes; Donida, Fernanda Araujo; Câmara, Andréa Cruz; Frazão, Marco.
  • Aguiar, Carlos Menezes; Federal University of Pernambuco. Faculty of Dentistry. Department of Prosthetics and Oral and Facial Surgery. Recife. BR
  • Donida, Fernanda Araujo; Federal University of Pernambuco. Faculty of Dentistry. Department of Prosthetics and Oral and Facial Surgery. Recife. BR
  • Câmara, Andréa Cruz; Federal University of Pernambuco. Faculty of Dentistry. Department of Prosthetics and Oral and Facial Surgery. Recife. BR
  • Frazão, Marco; s.af
Braz. j. oral sci ; 12(4): 307-312, Oct.-Dec. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-701318
ABSTRACT

AIM:

Cone beam computed tomography (CBCT) was used to evaluate the ability of three NiTi rotary systems to maintain the original root canal anatomy.

METHODS:

Sixty mesiobuccal canals of human mandibular first molars were divided into three groups with 20 root canals each. All teeth were scanned by CBCT before instrumentation. The images were captured digitally for further analysis using the Image Tools Software. The images were sectioned in three points, located at 9 mm, 6 mm and 3mm from the apex. In Group 1, the root canals were instrumented with ProTaper UniversalTM rotary system; in Group 2, with Twisted FileTM rotary system; and in Group 3, with MtwoTM rotary system. Instrumented teeth were scanned again using CBCT and the images of the uninstrumented canals were compared with images of the instrumented canals. The results were statistically analyzed using the one-way ANOVA test. A level of significance of 0.05 was adopted.

RESULTS:

The means of D1 at distances of 9 mm, 6 mm, and 3 mm from the apex were, respectively Group 1 0.88±0.257, 1.00±0.000, and 1.00±0.000; Group 2 0.79±0.745, 0.65±0.669, and 0.25±0; Group 3 0.50±0.745, 0.33±0.472, and 0.03±0.104. The means of D2 at distances of 9 mm, 6mm, and 3mm from the apex were respectively Group 1 1.00±0.00, 1.00±0.00, and 1.00±0.00; Group 2 0.41±0.299, 0.30±0.428, and 0.50±0.707; Group 3 0.58±0.910, 0.85±1.857, and 0.31±0.643.

CONCLUSIONS:

The CBCT analysis revealed that the ProTaper UniversalTM produced centered preparations and while the Twisted FileTM and MtwoTM rotary systems produced canal deviation.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Preparo de Canal Radicular / Cavidade Pulpar / Tomografia Computadorizada de Feixe Cônico Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Pernambuco/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Preparo de Canal Radicular / Cavidade Pulpar / Tomografia Computadorizada de Feixe Cônico Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Federal University of Pernambuco/BR