Your browser doesn't support javascript.
loading
The feasibility of an experimental model of donors after cardiac death in remote ischemic preconditioning studies for renal transplantation in porcine
Camarco, Joao Paulo Figueiredo; Morais, Lucio Kenny; Moreno, Juan Duque; Rassi, Matheus Castrillon; Camarco, Mylena Naves de Castro Rocha; Guimaraes, Pedro Figueiredo; Quireze Junior, Claudemiro.
  • Camarco, Joao Paulo Figueiredo; Universidade Federal de Goiás. Goiania. BR
  • Morais, Lucio Kenny; Universidade Federal de Goiás. Goiania. BR
  • Moreno, Juan Duque; Universidade Federal de Goiás. Goiania. BR
  • Rassi, Matheus Castrillon; Universidade Federal de Goiás. Goiania. BR
  • Camarco, Mylena Naves de Castro Rocha; Universidade Federal de Goiás. Goiania. BR
  • Guimaraes, Pedro Figueiredo; Universidade Federal de Goiás. Goiania. BR
  • Quireze Junior, Claudemiro; Universidade Federal de Goiás. Goiania. BR
Acta cir. bras ; 29(2): 82-86, 02/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-702523
ABSTRACT
To evaluate the feasibility of an experimental model of donors after cardiac death in remote ischemic preconditioning studies. METHODS: Twelve Landrace pigs were used as organ donors. They underwent cardiac arrest by coronary en block suture and interruption of ventilatory support. Haemodynamic data regarding the donor surgical protocol were evaluated. Studies variables included mean heart rate, systolic blood pressure, diastolic blood pressure, mean arterial pressure, central venous pressure and oxygen saturation and the time to death. RESULTS: Haemodynamic parameter indicated that the circulatory failure occurred after nine minutes of en block coronary suture and respiratory support interruption. The circulatory collapse occurred evenly across all groups. The heart rate and central venous pressure were statistically different between groups (p=0.023 and p=0.04), respectively. The remote preconditioning resulted in delayed time of death. CONCLUSIONS: The model is feasible, and was easily reproduced. The ischemic remote preconditioning tends to a slight increase in circulatory failure time.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Insuficiência Cardíaca / Isquemia Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Acta cir. bras Assunto da revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Goiás/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Insuficiência Cardíaca / Isquemia Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Acta cir. bras Assunto da revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Goiás/BR