Your browser doesn't support javascript.
loading
Correlación de los parámetros ecocardiográficos de estenosis aórtica en pacientes con fracción de eyección normal / Correlation of aortic stenosis echocardiographic parameters in patients with normal ejection fraction / Correlação dos parâmetros ecocardiográficos de estenose aórtica em pacientes com fração de ejeção normal
Contreras, Alejandro E.; Chamale², Roberto A.; Brenna, Eduardo J.; Parisi, Gustavo R.; Amuchástegui, Marcos.
  • Contreras, Alejandro E.; Hospital Privado Centro Médico de Córdoba. Servicio de cardiología. AR
  • Chamale², Roberto A.; Hospital Privado Centro Médico de Córdoba. Servicio de cardiología. AR
  • Brenna, Eduardo J.; Hospital Privado Centro Médico de Córdoba. Servicio de cardiología. AR
  • Parisi, Gustavo R.; Hospital Privado Centro Médico de Córdoba. Servicio de cardiología. AR
  • Amuchástegui, Marcos; Hospital Privado Centro Médico de Córdoba. Servicio de cardiología. AR
Insuf. card ; 8(4): 151-156, nov. 2013. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-708504
RESUMEN
Introducción. El ecocardiograma es el método de elección para evaluar la severidad de la estenosis aórtica (EA), pero a menudo existen discrepancias entre los parámetros ecocardiográficos. El objetivo de nuestro trabajo fue evaluar la correlación entre los parámetros ecocardiográficos utilizados para graduar la severidad de la estenosis aórtica: área valvular aórtica (AVA), gradiente transvalvular medio (GM) y velocidad sistólica máxima (VM), y valorar la discordancia entre el AVA y el GM para el diagnóstico de EA severa. Material y métodos. Se incluyeron de forma consecutiva pacientes a los que se les realizó un ecocardiograma transtorácico como parte del seguimiento de su estenosis aórtica. Se calculó el AVA por ecuación de continuidad, el AVA indexado (AVAi), la VM y el GM con Doppler continuo. Mediante el método de correlación bivariada se obtuvo el coeficiente de correlación de Pearson entre las variables AVA y AVAi-GM, AVA y AVAi-VM. Se consideró una p<0,05, estadísticamente significativa. Además, se dividió a la población en 4 grupos de acuerdo a los siguientes parámetros ecocardiográficos, AVA ≥1 cm² y <1cm²; AVAi ≥0,6 cm²/m² y <0,6 cm²/m² y GM ≥40 mm Hg y <40 mm Hg. Las variables categóricas se expresan en porcentaje y las variables continuas en promedio y desviación estándar. Resultados. Fueron incluidos 104 pacientes con un AVA promedio de 1,24 ± 0,40 cm², AVAi promedio de 0,67 ± 0,22 cm²/m², una VM promedio de 3,34 ± 0,89 m/seg y un GM promedio de 27,9 ± 17,6 mm Hg. Hubo correlación significativa entre las variables: AVA-GM (coeficiente de correlación 0,738; p<0,01), AVA-VM (coeficiente de correlación de 0,801; p<0,01). Se mantuvo la misma correlación cuando se comparó GM y VM con AVAi. Al dividir por grupos de acuerdo al área valvular y GM, hubo discordancia de los parámetros ecocardiográficos de estenosis aórtica severa en 12,5% y 17,3%, con AVA o AVAi, respectivamente. Conclusión. Existe correlación estadística entre los parámetros ecocardiográficos para evaluar la EA, pero hay discordancia de 12,5 ó 17,3% entre el AVA o AVAi, respectivamente, y GM para valorar EA severa.
ABSTRACT
Backround. Echocardiography is the method of choice for evaluating the severity of aortic stenosis, but there are often discrepancies between echocardiographic parameters. The aim of our study was to evaluate the correlation between echocardiographic parameters used to grade the severity of aortic stenosis: aortic valve area (AVA), mean transvalvular gradient (MG) and peak systolic velocity (PV) and assess the discordance between AVA and mean gradient for the diagnosis of severe aortic stenosis. Material and methods. We included consecutively patients who underwent transthoracic echocardiography as part of follow up of aortic stenosis. Was calculated AVA by continuity equation, indexed AVA (iAVA), PV and MG with continuous Doppler. By the method of bivariate correlation was obtained Pearson correlation coefficient between AVA and iAVA-MG, AVA and iAVA-PV. We considered a p<0.05 statistically significant. In addition, the population was divided into 4 groups according to the following echocardiographic parameters, AVA ≥1 cm² and <1 cm²; iAVA ≥0.6 cm²/m² and <0.6 cm²/m² and GM ≥40 mm Hg and <40 mm Hg. Results. We included104 patients with a mean AVA of 1.24 ± 0.40 cm², a mean iAVA of 0.67 ± 0.22 cm²/m², a mean PV of 3.34 ± 0.89 m/sec and a mean MG of 27.9 ± 17.6 mm Hg. There was significant correlation between the variables: AVA-MG (correlation coefficient 0.738, p<0.01), AVA-PV (correlation coefficient of 0.801, p<0.01). Remained the same correlation when compared iAVA with MG and PV. Dividing into groups according to valve area and MG, there was discrepancy of echocardiographic parameters of severe aortic stenosis in 12.5% and 17.3%, with AVA or iAVA respectively. Conclusion. Statistical correlation exists between echocardiographic parameters to assess aortic stenosis, but there is disagreement of 12.5 or 17.3%, between AVA or iAVA and mean gradient respectively to assess severe aortic stenosis.
RESUMO
Introdução. O ecocardiograma é o método de escolha para avaliar a gravidade da estenose aórtica, mas muitas vezes há divergências entre os parâmetros ecocardiográficos. O objetivo do nosso estudo foi avaliar a correlação entre os parâmetros ecocardiográficos utilizados para classificar a gravidade da estenose aórtica: área da válvula aórtica (AVA), gradiente transvalvular médio (GM) e velocidade sistólica máxima (VM), e avaliar a discordância entre AVA e GM para o diagnóstico de estenose aórtica grave. Material e métodos. Foram incluídos consecutivamente pacientes que se submeteram a ecocardiografia transtorácica como parte do monitoramento de sua estenose aórtica. A AVA foi calculada pela equação da continuidade, a AVA indexada (AVAi), a VM e GM com Doppler continuo. Pelo método de correlação bivariada foi obtido coeficiente de correlação de Pearson entre as variáveis AVA e AVAi-GM, AVA e AVAi-VM. Foi considerado uma p<0,05 estatisticamente significativa. Além disso, a população foi dividida em quatro grupos de acordo com os seguintes parâmetros ecocardiográficos, AVA ≥ 1 cm2 e <1 cm²; AVAi ≥0,6 cm²/m² e <0,6 cm²/m² e GM ≥40 mm Hg e < 40 mm Hg. As variáveis categóricas foram expressas em porcentagens e as variáveis contínuas em média e desvio padrão. Resultados. Foram incluídos 104 pacientes com uma AVA média de 1,24 ± 0,40 cm², AVAi média de 0,67 ± 0,22 cm²/m², uma VM média de 3,34 ± 0,89 m/seg e um GM média de 27,9 ± 17,6 mm Hg. Houve correlação significativa entre as variáveis: AVA-GM (coeficiente de correlação 0,738, p<0,01), AVA-VM (coeficiente de correlação de 0,801, p<0,01). Mesma correlação foi mantida quando comparado GM e VM com AVAi. Dividindo-se em grupos de acordo com a área da válvula e GM, houve discordância de parâmetros ecocardiográficos de estenose aórtica grave em 12,5% e 17,3%, com AVA ou AVAi, respectivamente. Conclusão. Existe correlação estatística entre os parâmetros ecocardiográficos para avaliar ...

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Insuf. card Assunto da revista: Cardiologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital Privado Centro Médico de Córdoba/AR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Espanhol Revista: Insuf. card Assunto da revista: Cardiologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital Privado Centro Médico de Córdoba/AR