Your browser doesn't support javascript.
loading
Tradução, adaptação cultural e validação para a língua portuguesa (Brasil) do Systemic Sclerosis Questionnaire (SySQ) / Translation, cultural adaptation and validation into portuguese (Brazil) in Systemic Sclerosis Questionnaire (SySQ)
Machado, Roberta Ismael Lacerda; Souto, Lais Medeiros; Freire, Eutilia Andrade Medeiros.
  • Machado, Roberta Ismael Lacerda; Universidade Federal da Paraíba. João Pessoa. BR
  • Souto, Lais Medeiros; Universidade Federal da Paraíba. João Pessoa. BR
  • Freire, Eutilia Andrade Medeiros; Universidade Federal da Paraíba. João Pessoa. BR
Rev. bras. reumatol ; 54(2): 95-101, Mar-Apr/2014. tab
Artigo em Português | LILACS | ID: lil-710215
RESUMO
Introdução: A esclerose sistêmica (ES) é uma doença multissistêmica, autoimune, caracterizada por disfunção fibroblástica e vasculopatia, causando grande impacto na qualidade de vida (QV). Esta é mensurada por instrumentos ou questionários, geralmente formulados em outros idiomas e inseridos em contextos culturais distintos. Objetivo: Traduzir, adaptar culturalmente e validar para a língua portuguesa (Brasil) o questionário do Systemic Sclerosis Questionnaire (SySQ) de QV em ES. Metodologia: Tradução e adaptação: etapa realizada de acordo com metodologia específica de tradução de questionários. Confiabilidade: foi analisada através de três entrevistas, realizadas por diferentes entrevistadores, sendo duas no mesmo dia (interobservação) e uma terceira após 14 dias (intraobservação). Validade: avaliada pela correlação clínica e parâmetros de QV com os domínios do Sysc. Análise estatística: realizada análise descritiva da amostra. A reprodutibilidade foi avaliada através de um coeficiente de correlação intraclasse (ICC) e a consistência interna pelo coeficiente alfa de Cronbach, já para analisar a validade utilizou o coeficiente de correlação de Spearman. Resultados: Foram observados 16 pacientes portadores de ES. Os nossos resultados foram semelhantes aos do questionário original, com a consistência interna variando entre 0,73 e 0,93 para cada item. A reprodutibilidade interobservador foi muito boa para todos os domínios (α = 0,786 a 0,983), e a intraobservador foi muito boa para o domínio de sintomas gerais (CCI = 0,916), boa para os domínios de sintomas musculoesqueléticos (CCI = 0,897) e cardiopulmonares (CCI = 0,842) e razoáveis para o de sintomas gastrintestinais (CCI = ...
ABSTRACT
Introduction: Systemic sclerosis (SSc) is a multisystem disease, autoimmune disorder characterized by a fibroblastic disfunction, with significant impact on quality of life (QoL), measured by instruments or questionnaires that usually were formulated in other languages and in different cultural contexts. Objective: Translate into Brazilian Portuguese, cross cultural adaptation and assess the reliability and validity of the Systemic Sclerosis Questionnaire (SySQ). Methodology: Translation and adaptation: into Portuguese and cross-cultural adaptation was performed in accordance with studies on questionnaire translation methodology into other languages. Reliability: it was analyzed using three interviews with different interviewers, two on the same day (interobserver) and the third within 14 days of the first assessment (intraobserver).Validity was assessed by correlating clinical and quality of life parameters with the domain scores of Sysc. Statistical analysis: a descriptive analysis of the study sample. Reproducibility was assessed using an intraclass correlation coefficient (ICC). Internal consistency was assessed using Cronbach's alpha coefficient. To assess validity we used Spearman correlation coefficient. Five percent was the level of significance adopted for all statistical tests. Results: In the evaluation of the questionnaires, the results were similar to the original questionnaire, the internal consistency ranging between 0.73 and 0.93 for each item. The interobserver reproducibility was very good for all domains (α = 0.786 to 0.983) and intraobserver agreement was considered very good for general symptoms domain (ICC = 0.916), good for musculoskeletal symptoms domain (ICC = 0.897) and cardiopulmonary domain (ICC = 0.842) and reasonable for gastrointestinal symptoms domain (ICC = 0.686). Conclusion: The Brazilian Portuguese version of SySQ proved to be reproducible and valid for our population, using a recognized ...
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Qualidade de Vida / Escleroderma Sistêmico / Inquéritos e Questionários Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. reumatol Assunto da revista: Reumatologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal da Paraíba/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Qualidade de Vida / Escleroderma Sistêmico / Inquéritos e Questionários Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. reumatol Assunto da revista: Reumatologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal da Paraíba/BR