Identificación, análisis y evaluación del riesgo de exposición ocupacional en servicios de preparación de citostáticos de la Red Nacional de Prestadores / Identification, analysis and risk assessment of occupational exposure in cytostatic preparation services of the Providers National Network
Cienc. Trab
;
16(49): 56-64, abr. 2014. ilus, tab
Artigo
em Espanhol
| LILACS
| ID: lil-710947
RESUMEN
Se identifica, analiza y evalúa el riesgo de exposición ocupacional a citostáticos, en una muestra de instalaciones destinadas a preparación de mezclas destinadas a tratamiento terapéutico oncológico, pertenecientes a la Red Nacional de Prestadores autorizados; en relación con el tipo y nivel de infraestructura de control y frecuencia de exposición asociada. Los resultados de la evaluación revelan una gran variedad de situaciones en las que, pese a la existencia de una regulación que define el tipo y caracteristicas de la contención mínima necesaria, se observan insuficiencias en el nivel de control observado y consiguiente riesgo al que se expone el personal. Del total de instalaciones incluidas en el estudio, sólo el 7% presenta un nivel de control aceptable y cercano al óptimo esperado, el 43% presenta un nivel de control regular y mejorable a través de correcciones menores. En tanto el 50% restante, revela un significativo nivel de insuficiencia; destacando que el 36% de las instalaciones evidencia condiciones extremas de exposición laboral.
ABSTRACT
The risk of occupational exposure to cytostatic was identified, analyzed and evaluated, in a sample of facilities used for preparation of mixtures for oncological therapeutic treatment, belonging to the National Network of Authorized Providers; regarding the type and level of infrastructure of control and frequency of associated exposure. The results of the evaluation reveal a great variety of situations where, despite the existence of a regulation that defines the type and characteristics of the minimum containment required, gaps are observed in the observed level of control and consequent risk which personnel is exposed to. From the total number of facilities included in the study, only 7% have a level of control acceptable and close to the optimal that is expected, 43% present a control level that is regular and improvable through minor corrections. Meanwhile, the remaining 50% show a significant level of insufficiency; it is underlined that 36% of facilities evidence extreme occupational exposure conditions.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Exposição Ocupacional
/
Medição de Risco
/
Citostáticos
/
Antineoplásicos
Tipo de estudo:
Estudo diagnóstico
/
Estudo de etiologia
/
Estudos de avaliação
/
Estudo prognóstico
/
Fatores de risco
Idioma:
Espanhol
Revista:
Cienc. Trab
Assunto da revista:
Medicina Ocupacional
/
Saúde Pública
Ano de publicação:
2014
Tipo de documento:
Artigo
País de afiliação:
Chile
Instituição/País de afiliação:
Asociación Chilena de Seguridad/CL
Similares
MEDLINE
...
LILACS
LIS