Your browser doesn't support javascript.
loading
Avaliação pelo MEF da distribuição das tensões no implante, componentes protéticos e coroa, em conexões com hexágono externo, interno e Cone Morse / Evaluation using FEM on the stressdistribution on the implant, prostheticcomponents and crown, with Cone Morse, external and internal hexagon connections
Formiga, Márcio de Carvalho; Inoue, Ricardo Tatsuo; Zanetti, Raquel Virginia; Zanetti, Artemio Luiz; Teixeira, Marcelo Luchesi; Takamatsu, Flávio.
  • Formiga, Márcio de Carvalho; s.af
  • Inoue, Ricardo Tatsuo; SLMandic. Campinas. BR
  • Zanetti, Raquel Virginia; SLMandic. Campinas. BR
  • Zanetti, Artemio Luiz; SLMandic. Campinas. BR
  • Teixeira, Marcelo Luchesi; s.af
  • Takamatsu, Flávio; SLMandic. Campinas. BR
Dent. press implantol ; 7(3): 67-75, July-Sept. 2013. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-718873
RESUMO
Objetivo: comparar a distribuição de tensões em sistemas de implantes com diferentes tipos de conexões (hexágono externo, hexágono interno e Cone Morse), pelo Método de Elementos Finitos Bidimensional. Métodos: uma força de 100N foi aplicada na cúspide vestibular de um segundo pré-molar inferior, no sentido axial, e, posteriormente, com inclinação de 45o em cada sistema. As análises foram realizadas pelos critérios das tensões de von Mises. Resultados: os resultados apontaram que, em todos os três sistemas, a maior concentração de tensões deu-se na região do pescoço do implante em contato com o osso cortical, com exceção do sistema Cone Morse, onde a tensão se concentrou na porção interna do implante em contato com o pilar. Também foi observado que cargas inclinadas sempre geraram valores superiores aos obtidos com as cargas axiais. Conclusão: pode-se concluir, então, que os parafusos dos pilares são a porção mais frágil dos sistemas. Nos implantes, os sistemas com conexão interna têm distribuição mais uniforme das tensões que o de conexão externa.
ABSTRACT
Objective: The aim of this study was to compare the stress distribution between implant systems with differenttypes of connections, i.e., external hexagon, internal hexagon and morse taper, by applying the Two-DimensionalFinite Element Method. Methods: A 100-N load was applied to the buccal cusp of an inferior second premolar inthe axial direction and thereafter at an inclination of 45o on each system. Analysis was performed by means ofthe von Mises stresses criteria. Results: The results showed that in, all systems, the highest stress concentrationoccurred in the neck of the implant in contact with the cortical bone, except for the morse taper models, where thestress was concentrated in the inner portion of the implant in contact with the abutment. It also became apparentthat oblique forces resulted in higher stress values than those obtained with axial loads. Conclusion: It could beconcluded that abutment screws are the most fragile portion of the systems. Internal connection implant systemsexhibited a more uniform distribution of stresses than external connection implant systems.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Estresse Mecânico / Análise de Elementos Finitos / Implantação Dentária / Análise do Estresse Dentário / Projeto do Implante Dentário-Pivô Tipo de estudo: Estudo prognóstico Idioma: Português Revista: Dent. press implantol Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: SLMandic/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Estresse Mecânico / Análise de Elementos Finitos / Implantação Dentária / Análise do Estresse Dentário / Projeto do Implante Dentário-Pivô Tipo de estudo: Estudo prognóstico Idioma: Português Revista: Dent. press implantol Assunto da revista: Odontologia Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: SLMandic/BR