RESUMO
Foram estudados olhos glaucomatosos de cães referidos no serviço de diagnóstico por imagem. Os pacientes foram submetidos à ultrassonografia em modo B de alta resolução para realização de biometria ocular, por meio da qual foram realizadas as seguintes medidas espessura central da córnea, profundidade da câmara anterior, espessura da lente e profundidade da câmara vítrea. Para tal, foi realizada contenção física e instilado colírio anestésico. Foram aferidas a PIO e a paquimetria da córnea e, em seguida, foi realizada a ultrassonografia em modo B nos dois olhos. Além da diferença óbvia de PIO, maior nos bulbos glaucomatosos, os resultados mostraram-se estatisticamente significativos em dois parâmetros aumento da profundidade da câmara vítrea nos casos de glaucoma crônico (1,24±0,26cm; P=0,01) quando se comparou aos olhos controle e aumento da espessura da córnea também nos casos de glaucoma agudo (0,987±0,28cm; P=0,027), quando se comparou aos olhos controle e aos olhos com glaucoma crônico. Observou-se que a câmara vítrea é a estrutura intraocular que mais contribui no processo de expansão de volume do bulbo (buftalmia) durante o glaucoma...
ABSTRACT
Dogs with glaucomatous eyes referred to the Diagnostic Image Service at the Veterinary Hospital in the Federal University of Parana were studied using B-mode ultrasonography. Patients were submitted to a high resolution B-mode ultrasonography examination in order to perform ocular echobiometry. The following measurements were performed central corneal thickness, anterior chamber depth, lens thickness and vitreous chamber depth. Physical restraint was performed and anesthetic eye drops were used. Corneal pachymetry and IOP were evaluated first and then B-mode ultrasonography was carried out in both eyes. Besides an obvious difference in IOP, which is higher in glaucomatous eyes, vitreous chamber depth significantly increases in cases of chronic glaucomatous eyes (1.24±0.26cm P=0.01), when compared to control eyes; and corneal thickness also increases in cases of acute glaucoma (0.987±0.28cm P=0.027), when compared to control eyes and to chronic glaucomatous eyeballs as well. Vitreous chamber is the intraocular structure that most contributes to the process of volume expansion of the globe (buphthalmos)...
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Glaucoma / Biometria / Córnea / Cães / Pressão Intraocular / Cristalino Tipo de estudo: Estudo diagnóstico Limite: Animais Idioma: Português Revista: Arq. bras. med. vet. zootec Assunto da revista: Medicina Veterinária Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Glaucoma / Biometria / Córnea / Cães / Pressão Intraocular / Cristalino Tipo de estudo: Estudo diagnóstico Limite: Animais Idioma: Português Revista: Arq. bras. med. vet. zootec Assunto da revista: Medicina Veterinária Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR