Avaliação transversal retrospectiva do desempenho clínico dos parafusos protéticos do sistema Implacil De Bortoli com cinco ou mais anos em função / A cross-sectional retrospective evaluation on the clinical performance of prosthetic screws of Implacil De Bortoli System with five or more years in function
ImplantNews
;
11(4): 514-518, 2014. ilus, tab
Artigo
em Português
| LILACS, BBO
| ID: lil-730889
RESUMO
Objetivos: relatar as falhas nos parafusos protéticos de um sistema de implantes com o tempo em função. Material e métodos: foram incluídos nesta avaliação transversal retrospectiva 183 pacientes, reabilitados com 916 implantes (Implacil De Bortoli) em função por pelo menos um ano. Dois grupos foram formados de acordo com o tempo em função: até cinco anos (G1) e mais de cinco anos (G2). A relação entre as falhas e o tempo de uso foi analisada pelo teste qui-quadrado (nível de significância 5%). Resultados: dos 916 implantes pesquisados, 836 (91,3%) não apresentaram falhas de parafuso e 80 (8,7%) mostraram algum problema relacionado. O grupo G1 apresentou 416 implantes, sendo que 404 implantes (97,1%) não apresentaram problemas e 12 implantes (2,9%) apresentaram falha de parafuso protético. No G2, foram selecionados 500 implantes, dentre os quais 432 (86,4%) apresentavam-se sem falhas de parafuso e 68 (13,6%) com presença de afrouxamento e/ou fratura do parafuso da prótese. Houve diferença estatística significante entre os grupos (p < 0,001). Conclusão: ambos os grupos apresentaram baixos índices de falhas nos parafusos. Entretanto, o G2 (próteses com mais de cinco anos) apresentou maior percentual dessas falhas, demonstrando que as mesmas aumentam com o tempo em função das reabilitações implantossuportadas.
ABSTRACT
Objectives: to report prosthetic screw implant failures over time periods. Material and methods: one-hundred and eighty-three patients receiving 916 implants (Implacil De Bortoli, Sao Paulo, Brazil) with at least one year to follow-up were included in this cross-sectional retrospective study. Prosthetic screws were divided into two groups: G1 (≤ 5 years) and G2 (> 5 years in function). The chi-square test was used to analyze relationship between failures and time in function (5% level of significance). Results: out of the 916 examined implants, 836 (91.3%) did not present prosthetic screw failures and 80 (8.7%) reported some problem. The G1 presented with 416 implants, being 404 (97.1%) with no problems and 12 (2.9%) with some type of failure. At G2, 500 implants were selected, being 432 (86.4%) presenting no failures and 68 (13.6%) with screw loosening and/or fracture. A statistically significant difference was observed between groups (p < 0,001). Conclusions: both groups presented low index failures for prosthetic screws. However, more failures were seen at G2 (> 5 years of follow-up), corroborating the findings that those increase according to time in function for oral, implant-supported rehabilitations.
Buscar no Google
Índice:
LILACS (Américas)
Assunto principal:
Implantes Dentários
/
Prótese Dentária Fixada por Implante
/
Falha de Restauração Dentária
Tipo de estudo:
Estudo observacional
/
Estudo de prevalência
Limite:
Adulto
/
Idoso
/
Aged80
/
Feminino
/
Humanos
/
Masculino
Idioma:
Português
Revista:
ImplantNews
Assunto da revista:
Odontologia
Ano de publicação:
2014
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
UFSC/BR
/
USP/BR
/
Unip/BR
Similares
MEDLINE
...
LILACS
LIS