Your browser doesn't support javascript.
loading
Evaluation of foraminal transportation during foraminal enlargement with different instrumentation systems
Silva, Diogo; Gomes, Aline Cristine; Silva, Juliana Melo da; Neves, Aline de Almeida; Zaia, Alexandre Augusto; Silva, Emmanuel João Nogueira Leal da.
  • Silva, Diogo; Universidade Estadual de Campinas. Piracicaba Dental School. Department of Endodontics. Piracicaba. BR
  • Gomes, Aline Cristine; Universidade Estadual de Campinas. Piracicaba Dental School. Department of Endodontics. Piracicaba. BR
  • Silva, Juliana Melo da; Universidade Federal do Rio de Janeiro - UFRJ. School of Dentistry. Department of Paediatric Dentistry. Rio de Janeiro. BR
  • Neves, Aline de Almeida; Universidade Federal do Rio de Janeiro - UFRJ. School of Dentistry. Department of Paediatric Dentistry. Rio de Janeiro. BR
  • Zaia, Alexandre Augusto; Universidade Estadual de Campinas. Piracicaba Dental School. Department of Endodontics. Piracicaba. BR
  • Silva, Emmanuel João Nogueira Leal da; Universidade do Grande Rio ­ UNIGRANRIO. School of Dentistry. Department of Endodontics. Rio de Janeiro. BR
Braz. j. oral sci ; 13(4): 246-250, Oct-Dec/2014. tab, graf
Artigo em Inglês | LILACS, BBO | ID: lil-732335
ABSTRACT

Aim:

To evaluate the foraminal transportation during foraminal enlargement after manual instrumentation with stainless steel files, preparation with the Mtwo system and Reciproc R25 file.

Methods:

Thirty roots were selected, divided in three groups and prepared in accordance with the different instrumentation systems Hand Files (HF); Mtwo system (MS); and Reciproc system (RS). All groups were prepared with the instrumentation level 1 mm beyond the apex. Photomicrographs were performed using scanning electron microscopy, to record the foraminal anatomy before and after instrumentation. Data were analyzed using ANOVA followed by Tukey's test with a significance level of 5%.

Results:

The group instrumented with hand files showed higher foraminal transportation when compared to the Mtwo and Reciproc groups (p<0.05). Reciproc group showed lower transportation when compared to the Mtwo group (p<0.05).

Conclusions:

The stainless steel files caused significant foraminal transportation, while Reciproc system showed safe apical preparation, with little transportation.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Endodontia / Anatomia Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Campinas/BR / Universidade Federal do Rio de Janeiro - UFRJ/BR / Universidade do Grande Rio ­ UNIGRANRIO/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Endodontia / Anatomia Idioma: Inglês Revista: Braz. j. oral sci Assunto da revista: Odontologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Campinas/BR / Universidade Federal do Rio de Janeiro - UFRJ/BR / Universidade do Grande Rio ­ UNIGRANRIO/BR